An integrated system for interstitial 192Ir implants.

Abstract

An efficient system for preparing, afterloading, and removing interstitial 192Ir strands has been developed. Use of the system reduces the risk of personnel exposure and eliminates some patient discomfort. The system is "integrated" in that all aspects of the implantation process are considered, from source preparation to source removal. Strand preparation is facilitated by an "assembly line" process using shielded equipment. Components include a handling block for measuring and cutting active strands, a mirror, and a transport container. Afterloading and removal techniques use quick release devices and several forms of afterloading tubing and catheters, each terminated by a Luer lock adapter. Both blind-end and through-and-through implants are possible. Each 192Ir strand, threaded through an injection cap that mates with the Luer lock adapter, is quickly inserted into its tubing or catheter and locked into place. No crimping is required and no additional positioning of the sources is needed. Strand removal is easily accomplished by unlocking and removing the injection cap. The strands receive no mechanical damage and can be reused after appropriate cleaning. More than 100 cases have been performed without incident. Applications include head/neck, breast, and template and non-template vaginal wall treatments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Bourland, K L Reynolds, E L Chaney, M A Varia, J G Rosenman, H L McMurry, A D Simons. 1987. An integrated system for interstitial 192Ir implants.. https://doi.org/10.1016/0360-3016(87)90020-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intraoperative optimization of needle placement and dwell times for conformal prostate brachytherapy.

PURPOSE: Traditionally, transperineal prostate brachytherapy has been heavily operator dependent. To overcome this limitation, a treatment planning method was developed for intraoperative planning, guidance, and evaluation. In this setting, reliability, speed, and ease of understanding are primary considerations. This planning method has been implemented for ultrasound guided implants of the prostate, but can be extended for use in other body sites. METHODS AND MATERIALS: The length and cross-section of the target (prostate) and location of urethra and rectum are determined intraoperatively from live ultrasound imaging. The planning program then automatically generates a "reference plan" containing needle locations, dwell times, and the resulting isodose distribution. As needles are placed, this information is corrected to account for any deviation of needle placement or movement of the prostate. Once all needles are in place, the normalization is adjusted to reconcile remaining hot-spots with coverage of the target volume. Optimization is performed in three separate stages. Each stage works to enhance only a subset of the implant parameters. (a) Pattern Optimization attempts to find the most appropriate placement for the needles or catheters. It is based on the transverse contour of the target volume. Needles are placed uniformly around the perimeter, and interior needle positions are determined from the cross-sectional area and shape. Critical structures such as the urethra are explicitly avoided. This step provides the overall framework for the implant, and is not generally repeated. (b) Relative Dwell Time Optimization selects relative dwell times that will give the best uniformity of dose. It works by setting the relative dwell time in each source position inversely proportional to the dose delivered to that point by the other source positions. It is used in the reference plan, and is repeated as each needle is inserted. This provides dosimetric feedback to the physician, who can judge the effect of deviations from the reference plan. (c) Relative Volume Optimization is an interactive method for fine tuning the normalization based upon volume analysis. The volume analysis is presented in tabular and graphical form, both being updated rapidly as the normalization is adjusted. The information is formatted to help the operator judge coverage and uniformity. Special functions are provided that allow the operator to "jump" to special normalization values based on several indices of uniformity or uniformity/coverage. RESULTS: This system overcomes some conventional brachytherapy limitations. Rather than depend on the operator's intuitive judgement of where the needles should be placed, a global plan is generated and validated with full dose calculations. Immediate feedback is provided concerning the adequacy of placement and avoidance of critical structures. This information is provided in terms of actual tissue doses to the target volume and critical structures using point doses, isodose distributions, and volume analysis. Since the new method was introduced in January 1994, 33 implants have been performed. The needle placement method has been reliable in the clinic, with different doctors producing similar results on subsequent fractions for the same patient. CONCLUSION: The method of decomposing the optimization problem into several simple steps is capable of rapidly, consistently, and reliably designing conformal treatment plans of high uniformity. Operator dependence has been significantly reduced. We are adapting the method for other anatomic sites.

Brachytherapy

Clinical use of a digital simulator for rapid setup verification in high dose rate brachytherapy.

PURPOSE: Fractionated high dose rate (HDR) brachytherapy provides a number of technical advantages over conventional implant therapy in that (a) it can be carried out on an outpatient basis, (b) personnel exposure is reduced to insignificant levels, and (c) patient motion during irradiation is minimized, resulting in a more accurate delivery of the planned radiation dose distribution to the target and critical structures. The patient discomfort associated with the repeated applicator insertions and/or treatment setups can be alleviated to the extent that the setup time is held to a minimum. This work describes the use of a prototype digital simulator to obtain fast, high-quality digital images for rapid setup verification. METHODS AND MATERIALS: The digital imaging system of the prototype simulator consists of a charge-coupled device (CCD) camera, which views the x-ray image optically transmitted from a conventional phosphor screen. Treatment is carried out with a remote afterloading HDR unit immediately after setup verification with the patient on the simulator stretcher. The high-resolution digital images are processed and displayed in about 5 s, as opposed to a minimum of approximately 2 min for film. RESULTS: The imaging system has been evaluated for a variety of implant types, both intracavitary and interstitial. The digital radiographs provided permanent high-resolution images as required in most cases for precise applicator positioning. The gray scale manipulation capabilities were found to be useful for imaging in regions of different density, such as lung and soft tissue, in the same radiograph. The advantages of short image acquisition and display times were observed in all cases, but were most evident in the intraluminal procedures, which sometimes involved several pretreatment applicator adjustments at a time of considerable patient discomfort. CONCLUSION: Pretreatment imaging is necessary to fully exploit the technical advantages of HDR brachytherapy. High-quality digital radiography offers unique advantages in HDR setup and verification by providing fast high-resolution, undistorted images with software manipulation capabilities and permanent storage of images.

Brachytherapy

Interstitial hyperthermia and iridium-192 treatment alone vs. interstitial iridium-192 treatment/hyperthermia and low dose cisplatinum infusion in the treatment of locally advanced head and neck malignancies.

PURPOSE: To determine whether the addition of low dose platinum infusional chemotherapy adds to the effectiveness of interstitial hyperthermia/iridium-192 management of locally advanced head and neck malignancies. METHODS AND MATERIALS: From 1987 to 1993, 36 patients with locally advanced head and neck malignancies were treated locally with interstitial hyperthermia and iridium-192 as part or all of their management. Twenty-two of the above-mentioned patients also received low dose infusional cisplatinum chemotherapy at 20 mg/M2 per day during the time of the implant. No patient received greater than 100 mg/M2 total dose. Implant times ranged from 38.5 to 134 h and total doses delivered with the radiation implants ranged from 15 to 39.9 Gy. Average implant volume was 50 cc. Twenty-three patients received external beam irradiation supplementation in a dose range from 25.2 to 64 Gy. RESULTS: Median follow-up for the entire group was 8, months with 7 months for the chemotherapy group vs. 12 months for the no-chemotherapy group. Freedom from relapse rates for the chemotherapy group vs. the no-chemotherapy group were 70% at 41 months vs. 63% at 60 months, p = not significant (p = NS). Overall survival by Life Table Analysis was 28% for the chemotherapy group at 41 months vs. 31% for the no-chemotherapy group at 60 months (p = NS). Complete response (CR) rates were 93% for the chemotherapy group vs. 86% for the no-chemotherapy group. Seven patients in the chemotherapy group had recurrent disease and four patients in the no-chemotherapy group were being treated for recurrent disease. Complication rates were similar in both groups, with two patients in the chemotherapy arm requiring hyperbaric oxygen treatments and one patient in the no-chemotherapy arm requiring hyperbaric oxygen treatments (for soft tissue necrosis). CONCLUSION: It appears that low dose platinum infusional chemotherapy can be added safely to patients receiving interstitial iridium-192 implants along with interstitial hyperthermia for head and neck malignancies. Although there appears to be a trend toward better freedom from relapse by adding chemotherapy, a larger trial and longer follow-up will be necessary to prove statistical significance. Further research in these areas is recommended in the form of a randomized prospective study.

Brachytherapy