PubMed Health⌕ Search

PubMed · 3683312

Wobbler facility for biomedical experiments.

Abstract

A system for spreading relativistic heavy ion beams into large uniform radiation fields has been developed. The charged particles passing through the system are deflected into azimuthally symmetric distributions which can then be superimposed to produce dose distributions as large as 30 cm in diameter with less than +/- 3.5% variation in uniformity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T R Renner, W T Chu. Wobbler facility for biomedical experiments.. https://doi.org/10.1118/1.596009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of fragment reaction of relativistic heavy charged particles on heavy-ion radiotherapy.

The production of projectile fragments is one of the most important, but not yet perfectly understood, problems to be considered when planning for the utilization of high-energy heavy charged particles for radiotherapy. This paper reports our investigation of the fragments' fluence and linear energy transfer (LET) spectra produced from various incident ions using an experimental approach to reveal these physical qualities of the beams. Polymethyl methacrylate, as a substitute for the human body, was used as a target. A deltaE-E counter telescope with a plastic scintillator and a BGO scintillator made it possible to identify the species of fragments based on differences of various elements. By combining a gas-flow proportional counter with a counter telescope system, LET spectra as well as fluence spectra of the fragments were derived for each element down from the primary particles to hydrogen. Among them, the information on hydrogen and helium fragments was derived for the first time. The result revealed that the number of light fragments, such as hydrogen and helium, became larger than the number of primaries in the vicinity of the range end. However, the greater part of the dose delivered to a cell was still governed by the primaries. The calculated result of a simulation used for heavy-ion radiotherapy indicated room for improving the reaction model.

Ions↗

Calculated and experimental geometries and infrared spectra of metal tris-acetylacetonates: vibrational spectroscopy as a probe of molecular structure for ionic complexes. Part II.

Following on from our previous work on Sc, Fe, Cr, and Al (Part I; see J. Phys. Chem. A, 105 (2001) 238), the geometries and infrared spectra of the trivalent metal tris-acetylacetonate complexes (M[O2C5H7]3; M = Ti, V, Mn, Co) have been studied both experimentally and theoretically using nonlocal hybrid density functional theory with a split-valence plus polarization basis for the ligand and valence triple-zeta for the metal. Unlike the D3 complexes studied in Part I, those of Ti, V and Mn are candidates for Jahn-Teller distortion due to fractional d-shell occupancy. Using scale factors transferred from Part I, our calculated frequencies are in very good agreement with experimentally observed fundamentals. Our investigation shows that the V and Mn complexes distort to C2 ground states, but D3 Ti tris-acetylacetonate is stable. Further investigation of the weak band observed around 800 cm(-1) in the Fe complex (and present in almost all studied first-row transition metal tris-acetylacetonates), which we were unable to assign theoretically in Part I, supports the argument that this band is not a fundamental but is due to Fermi resonance.

Ions↗

On-line ion-exchange preconcentration and determination of traces of platinum by electrothermal atomic absorption spectrometry.

A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 microL, a linear calibration graph was obtained in the range 0-100 ng mL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.

Ions↗