A technique to evaluate the performance of computerized ECG analysis systems.

Abstract

No objective method to test computerized ECG systems has been available. Until now, tests have been conducted separately for instrumentation and algorithms. Hence, to facilitate objective verification and testing of modern computerized ECG equipment, a dedicated high resolution, low noise instrument (an "electronic test patient") has been developed. The purpose of this communication is to describe this new instrument and its electrocardiographic database. The instrument is designed not to cause any disturbances to the original ECG signals in the frequency range from 0 to 1 kHz. The input channels accommodating standard 12-lead and 3-lead Frank systems are sampled simultaneously at 10 kHz each with 90 dB dynamic range. The overall RMS noise figure of the instrument is 1 microV. The integral part of the instrument is a high resolution, high bandwidth minidatabase consisting of selected A-type and B-type verified electrocardiograms such as infarctions, ventricular hypertrophies, atrial fibrillations, etc. The minidatabase was collected with the aid of a computerized ECG system, which has a program for searching for specific electrocardiographic diagnosis. Each database record consists of simultaneous electrocardiographic signals of all standard leads and Frank leads, and a validated diagnostic report. A system under test is typically connected via its patient cable to the analog output of the instrument. The testing is performed with reference to the validated ECG from the database. In that way, our minidatabase is compatible with any electrocardiographic system. The only similar database assembled for testing purposes is that of the CSE group.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Teppner, S Lobodzinski, D Neubert, M M Laks. 1987. A technique to evaluate the performance of computerized ECG analysis systems.. https://pubmed.ncbi.nlm.nih.gov/3694104/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗