PubMed HealthSearch

PubMed · 3740664

[Digestive system duplications].

Abstract

Fifteen digestive duplications, corresponding to fourteen patients, have been surgically treated in "La Paz" Pediatric Hospital between 1966 and 1984. The most common localization (40%) was the large bowel. The first choice treatment was the complete excision of lesions, with led to cure of all patients. Embryologic theories and clinical forms are also reviewed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Mariño, M J Martínez-Urrutia, P Santamaría, A Queizán, J G Utrilla. 1986. [Digestive system duplications].. https://pubmed.ncbi.nlm.nih.gov/3740664/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Laparoscopic treatment of paraesophageal and large mixed hiatal hernias.

BACKGROUND: Laparoscopic treatment of large mixed hiatal hernias was attempted in eight patients. METHODS: One patient (12.5%) was converted to open surgery due to difficulty in repositioning the LES into the abdomen resulting from a shortened esophagus. One left pleural tear occurred intraoperatively and was repaired without further consequence. Median duration of the operation was 150 min (range 120-300 min). RESULTS: No postoperative complications were recorded. All patients are asymptomatic after a median follow-up of 14 months (range 7-15 months). Correct repositioning of the stomach was confirmed by radiological evaluation 1 month after surgery. Early functional results are good. (One asymptomatic gastroesophageal reflux was detected and medical treatment was undertaken). CONCLUSIONS: Laparoscopic crural repair and fundoplication are feasible even in paraesophageal and large mixed hiatal hernias. Advantages of the minimally invasive approach are clear in terms of morbidity, patient comfort, and duration of hospital stay. Nevertheless, long-term assessment is required to confirm the effectiveness of the laparoscopic approach in patients with large mixed hiatal hernias.

Esophagus

The glucose-6-phosphatase enzyme in developing human trachea and oesophagus.

Glucose-6-phosphatase is an endoplasmic reticulum system which is found primarily in liver and kidney. Recently, it has become clear that it is also present in lower amounts in a variety of other tissues. Previous histochemical studies of glucose-6-phosphate hydrolysis in trachea have given equivocal results and only one study on adult oesophagus has shown glucose-6-phosphatase, enzymatic activity but without cellular localization. We have now shown, using microassay techniques, that microsomes isolated from human foetal trachea and oesophagus both contain low levels of specific glucose-6-phosphatase activity (mean = 0.9 and 1.5 nmol min-1 mg-1 microsomal protein, respectively) which are less than 10% of the levels in microsomes of human foetal liver of similar age. In the developing trachea, glucose-6-phosphatase immunoreactivity has been found, using a monospecific antibody to the catalytic subunit of the glucose-6-phosphatase enzyme, to be first present at 10-11 weeks' gestation, and thereafter in foetal life, predominantly present in ciliated cells, with smaller amounts in non-ciliated secretory cells, duct lining cells, and occasional basal cells. The foetal oesophageal epithelium is transiently ciliated from 10 to 11 weeks' gestation, but ciliated cells are gradually replaced by squamous cells from 14 to 16 weeks onwards. Glucose-6-phosphatase immunoreactivity in human foetal oesophagus is predominantly confined to ciliated cells, but non-ciliated luminal cells are also reactive, as are occasional basal cells. Mucus secretory cells in foetal trachea and oesophagus are immunonegative, as is the entire epithelium of both organs in the embryo (up to 56 postovulatory days.

Esophagus

[The transillumination technique. An alternative to conventional intubation?].

The technique of light-guided intubation is based on the principle that a source of light brought into the trachea results in clearly visible and defined transcutaneous illumination, while no illumination can be observed with the light source in the oesophagus (Fig. 1-7). The Trachlight is a reintroduced instrument for this alternative intubation technique. The essential developments are: a length-adjustable stylet with a removable internal metal wire, a brighter light source, a stable handle with tight fixation of the endotracheal tube, and a time-dependent warning device to avoid extended intubations. One hundred twenty patients (Mallampati I. ASA I-III) were included in the study (conventional intubation [group KL, n = 60]. Trachlight intubation [group TT, n = 60]. The goals of the investigation were to examine the handling, application, problems, limitations, and possible indications of the method. The recorded parameters were: number of intubation attempts: course and duration of intubation; complications; and difficulties. In 40 patients (20 in each group) the indication for invasive blood pressure measurement was given due to the surgical procedure, and circulatory parameters were recorded at defined moments during the intubation course. In group KL 55 patients were intubated in the attempt, 4 on the second, and 1 on the third (mean duration 23.6 +/- 10.4 s, range 12-60 s). Complications were: unilateral intubation (3 patients), bradycardia (2), asystole (1) and soft-tissue injury (1). Of the 60 patients in group TT. 54 were intubated successfully, the mean time needed being 29.9 +/- 14.8 s (range: 6-61 s). The remaining 6 were then intubated by the conventional method. Positive results in group TT included: easy handling and application, no injury to soft tissues or teeth, and invariably correct placement of the tube. Problems included: sufficient transillumination was achieved only after (entire) dimming of the room, insufficient control over the distal end of the tube due to an unfixed metal wire, unintentional switching off of the light while with-drawing the metal wire, difficulties in withdrawing the metal wire (too strong fixation), as well as disturbing effects of the warning device (blinking of the light 30 s after switching on). Reasons for the 6 intubation failures were introduction of the instrument into the oesophagus despite a supposed correct position, impossibility of correct placement in a patient with an extremely large goiter, and insufficiently clear transillumination in 3 extremely obese patients. The cardiovascular parameters showed no changes during laryngeal manipulation; a clear rise in heart rate and blood pressure was recorded, however, when the tube was inserted into the trachea. The cardiovascular parameters during conventional intubations were similar. The light-guided intubation technique can be regarded as a further alternative for airway management, due to the described improvement of the instrument. The indication for the technique is given in patients in whom no difficulty with intubation is expected, to avoid soft tissue damage and traumatising temporomandibular joint movements. Preclinical use may be limited due to environmental brightness. In patients with expected difficult airway management, fiberoptic intubation will remain the method of choice.

Esophagus