A microcomputer-based data acquisition system for a prosthetic heart valve test apparatus.

Abstract

The hydrodynamic testing of prosthetic heart valves in the laboratory under pulsatile flow conditions remains the only way of obtaining detailed information about valve function. Test procedures have become increasingly sophisticated, with a variety of different test conditions and detailed analysis of the pressure and flow signals. A computerized data acquisition system has been developed for use with the Glasgow pulsatile flow test apparatus. The computer collects seven signals from the test rig over a period of 20 s, and calculates the average waveform for each signal. Standard parameters, such as mean pressure differences, mean flows, regurgitant volumes and energy losses, are calculated automatically. The complexity of the analysis and the need for standardized documentation makes computerization essential. The system has been used extensively for function tests on over 160 prosthetic heart valves.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I MacDonald, J Fisher, A L Evans, D J Wheatley. A microcomputer-based data acquisition system for a prosthetic heart valve test apparatus.. https://doi.org/10.3109/03091908609022924

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗