[Harmful interference between preoperative prophylactic cardiac pacemaker and cutting diathermy. Case report].

Abstract

The authors report the case of a patient suffering the consequences of harmful preoperative between a prophylactic cardiac pacemaker system and cutting diathermy, resulting in irreversible ventricular fibrillation. After reviewing the different mechanisms responsible for this accident, they attribute the blame to a phenomenon of capture of electromagnetic currents with the pacemaker catheter playing the role of an aerial. They reconsider the indications for the use of prophylactic pacing and recall the safety precautions which must be respected at the time of simultaneous use of an external pacemaker and cutting diathermy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Protin, B Dodinot, J C Lefèvre, M C Laxenaire. 1979. [Harmful interference between preoperative prophylactic cardiac pacemaker and cutting diathermy. Case report].. https://pubmed.ncbi.nlm.nih.gov/38707/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Understanding submucosal electrosurgery for the treatment of nasal turbinate enlargement.

The surgical management of inferior turbinate enlargement is controversial. Submucosal electrosurgical techniques for turbinate reduction include conventional diathermy, radiofrequency tissue reduction and coblation. All electrosurgical techniques use radiofrequency electricity to damage turbinate tissue but differ in the control and delivery of energy. This review will examine the history of submucosal electrosurgery and clarify the various techniques. This review will also examine the evidence for the efficacy and safety of electrosurgery for the treatment of nasal turbinate enlargement, and will make a case that no progress will be made in clinical trials on the safety and efficacy unless there is standardisation of equipment and techniques in nasal electrosurgery.

Diathermy↗

Measurement of the specific heat capacity of liver phantom.

Phantoms are often used to simulate tissue during the development, testing and calibration of medical devices. In order to infer the specific absorption rate (SAR) and resistive heating in phantoms from temperature measurements, the specific heat capacity and density of the phantom are needed. Stauffer et al (2003 Int. J. Hyperth. 19 89-101) developed several phantoms that mimic dielectric properties of liver tissue at 915 MHz. However, thermal properties of the phantoms were not presented. We have measured specific heat capacities and densities for these phantoms. We also present dielectric properties for these phantoms measured from 0.7 to 20 GHz, including 2.45 GHz--a commonly used frequency for microwave hyperthermia and ablation.

Diathermy↗