PubMed HealthSearch

PubMed · 3960106

Serial and parallel processing of visual feature conjunctions.

Abstract

Treisman and others have reported that the visual search for a target distinguished along a single stimulus dimension (for example, colour or shape) is conducted in parallel, whereas the search for an item defined by the conjunction of two stimulus dimensions is conducted serially. For a single dimension the target 'pops out' and the search time is independent of the number of irrelevant items in the set. For conjunctions, the search time increases as the set becomes larger. Thus, it seems that the visual system is incapable of conducting a parallel search over two stimulus dimensions simultaneously. Here we extend this conclusion for the conjunction of motion and colour, showing that it requires a serial search. We also report two exceptions: if one of the dimensions in a conjunctive search is stereoscopic disparity, a second dimension of either colour or motion can be searched in parallel.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Nakayama, G H Silverman. Serial and parallel processing of visual feature conjunctions.. https://doi.org/10.1038/320264a0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Readability and sensitivity of a new faecal occult blood test in a hospital ward environment. Comparison with an established test.

OBJECTIVE: To compare the readability and sensitivity of a new guaiac faecal occult blood test, HemoccultSENSA, with those of a standard guaiac-based test, Hemoccult, in a normal working environment. DESIGN: The two tests were performed in parallel on routine clinical and contrived faecal specimens; those developing the tests were blinded as to the test type. SETTING: All tests were carried out in the hospital ward environment under normal conditions by nurses working in the ward. SAMPLES: Fifty faecal samples from healthy volunteer subjects (low concentrations of haemoglobin were added to 40 of these samples) and 145 faecal samples from 65 inpatients likely to have gastrointestinal bleeding. MAIN OUTCOME MEASURES: Test positivity rate, and graded measures of colour intensity, colour stability and colour pattern. RESULTS: With patients' samples, the new test gave a greater number of positive results than the standard test (73.1% v. 65.5%; 95% confidence interval of the difference, 3.3%-11.9%). With contrived samples, the blue colour produced during development was more intense (P less than 0.0003), more stable (P less than 0.0025) and covered a larger area (P less than 0.01) with the new test compared with the standard test. CONCLUSIONS: These results demonstrate the better readability and slightly higher sensitivity of the new test. They justify its use in the ward environment or doctor's office. Patients being tested should consume a low peroxidase diet until the specificity of the new test has been fully evaluated.

Color