Noninvasive recording of His bundle electrograms using vectorial leads system.
Abstract
His bundle electrograms were recorded in 8 rats by a signal averaging technique using the Takayasu vectorial lead system. Animals were anesthetized and placed in the prone position. The polarity of three orthogonal leads were: the X axis, from right to left; the Y axis, from top to bottom; the Z axis, from back to front. Potentials from the X, Y, and Z leads were amplified by 20,000 with high-pass 12 dB/octave filtering at 80 Hz, and signal averaging of 2000 beats was performed at a sampling interval of 100 microseconds. The His bundle potential could be clearly defined in all 8 rats. The mean amplitude of the His potential was larger in the X-axis (23.6 +/- 9.2 mu V) or the Y-axis (28.4 +/- 14.5 mu V) than the Z-axis lead (11.5 +/- 8.6 mu V). Directions of the His potential vectors were to the left in 5 of 8 rats (62.5%), to the caudal in 4 of 6 rats (66.7%), and to the dorsal site in 6 of 8 rats (75.0%). This vectorial lead system, devised in accordance with McFee and Johnston's theory on lead field, was useful for recording His bundle electrograms.