The theoretically ideal donor site dressing.

Abstract

Many of the choices for managing split-thickness skin graft donor sites are satisfactory, but none is ideal. Epidermal regeneration in a donor site is readily available for clinical study. We have reviewed experimental studies of epidermal regeneration and applied those results to the clinical study of a new donor site dressing. This dressing is a vapor-permeable, transparent, polyurethane film with a polyvinyl ether adhesive. Used on 100 patients, it was found to be safe and effective in allowing rapid and painless healing. Although the dressing is occlusive and theoretically could promote infection in a contaminated wound, no infections were encountered. Comparison was made with 15 patients managed by other methods. No marked difference in healing time was noted clinically. The striking advantage of the new dressing was painless healing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D C Birdsell, K S Hein, R L Lindsay. 1979. The theoretically ideal donor site dressing.. https://doi.org/10.1097/00000637-197906000-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Whitehead's varnish nasal pack.

Whitehead's varnish is a little known but excellent nasal packing agent. We review available literature on the historical aspects and clinical use of Whitehead's varnish. Our personal experience with Whitehead's varnish is described, and we strongly recommend its use.