Internal interactions within the human circadian system: the masking effect.

Abstract

In the realm of human circadian rhythms, the masking effect is defined as the change in the course of deep body temperature induced by changes in the degree of physical activity, or by the alteration between sleep and wake. This effect is particularly obvious during internal desynchronization where the rhythms of deep body temperature, and the sleep-wake sleep cycle - i.e. one of the masking factors - run with different periods. Every sleep onset is accompanied by a rapid drop, and wake onset by a rapid rise in deep body temperature, each one with an overshoot of about 50% of the steady state variations. When rhythms are calculated, with the dominant temperature period as the screening period, exclusively from data obtained during sleep episodes, on the one hand, and from those obtained exclusively during wake, on the other, two average cycles emerge: the 'sleep temperature curve' and the 'wake temperature curve'. Both run in parallel but are separated by the 'masking effect'. As derived from many experiments, the mean masking effect amounts to 0.28 +/- 0.06 degree C. The masking effect also depends to some extent on the phase of the temperature rhythm; it is larger than average around the temperature maximum and during the descending phase of the temperature cycle, where the alertness commonly is highest and the probability to sleep, in general, and the REM sleep propensity, in particular, are smaller than average. This also can be interpreted to indicate that the sleep temperature curve is phase advanced relative to the wake temperature curve; this, on the average, by 0.9 +/- 0.3 h. If the individually determined amount of masking is added to the temperature data obtained during sleep, or subtracted from the temperature data obtained during wake, a temperature curve emerges that can be thought of as being 'purified' of the masking effect. Analyses of this artificial curve allow estimation of that part of the internal interactions uninfluenced by the masking effect. On the average, about half of the amount of interaction between the rhythm of sleep-wake and that of deep body temperature is explained by the masking effect, whereas the other half is 'oscillatory interaction'. Both types of interaction are inherent and inseparable parts of the circadian clock mechanism, as can be deduced from model considerations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Wever. 1985-03-15. Internal interactions within the human circadian system: the masking effect.. https://doi.org/10.1007/bf02004495

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗