PubMed Health⌕ Search

PubMed · 4010879

[Evaluation of anticonvulsant-induced bone changes by a microdensitometric method].

Abstract

The effect of long-term anticonvulsants on bone change was evaluated by microdensitometric method (MD method) in 221 outpatients of Neurological Institute Tokyo Women's Medical College. Laboratory findings including serum Ca, P, Al-p were compared with severity of bone change. Following results were obtained; In 221 patients, 159 cases (72%) were normal, 31 cases (14%) were in the initial stage of abnormality, 23 cases (10%) in grade I, 7 cases (3%) in grade II and one case (1%) in grade III of abnormality. Incidence of abnormality was high in the age of 26-35 years old and in the age over 56 years old. Total dose, serum concentration of diphenylhydantoin (DPH) as well as phenobarbital (PB) and also duration of administration of PB correlated positively with severity of bone change. Duration of administration of DPH and valproic acid (VPA), total dose and serum concentration of VPA did not correlate with severity of bone change. Serum Ca correlated with severity of bone change, but P and Al-p did not correlate with severity of bone change. Pattern of bone change was estimated by two parameters of MD method (MCI and GSmax). Results showed that most of the osteopathy (grade I-III by MD method) fell into osteoporotic type. Based on these results, it is suggested that roentgenologic and biochemical supervision of the patients is required during long-term anticonvulsant therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Iwata, K Amano, H Kawamura, T Tanikawa, H Kawabatake, M Notani, H Iseki, T Shiwaku, T Nagao, T Taira. 1985. [Evaluation of anticonvulsant-induced bone changes by a microdensitometric method].. https://pubmed.ncbi.nlm.nih.gov/4010879/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗