Alternobaric effects on the endolymph.

Abstract

Hearing loss and vertigo experienced as a result of environmental pressure change has been the subject of many superficial inquiries. The mechanism of these conditions remains obscure. In human volunteers and a rhesus monkey, the effects of intratympanic as well as ear canal pressure changes on the endolymphatic system were measured using electronystagmography (ENG). For the monkey histological evaluation of the pressure effects on auditory structures was performed. We were unable to cause any ENG effects on the monkey neither did we produce intracochlear pathology. The data obtained in humans using a similar approach are presented and explanations for the mechanism related to hearing loss and vertigo in barotrauma are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Holmquist, P Lindeman. Alternobaric effects on the endolymph.. https://pubmed.ncbi.nlm.nih.gov/403903/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gene transfer to tumor-infiltrating lymphocytes and other mammalian somatic cells by microprojectile bombardment.

We demonstrate the application of particle delivery to the transformation of mammalian somatic cells. Two mouse T-lymphocyte cell lines and Chinese hamster ovary (CHO) cells were transformed transiently with the RSV-ADH (alcohol dehydrogenase) gene. Stable gene transfer was also demonstrated in CHO cells at a frequency of 6 x 10(-4) and in T-cells at a frequency of 1 x 10(-4), using beta-Gal/neomycin-resistance gene constructs. The helium gas acceleration mechanism (PDS 1000/He) and particle delivery method allowed better velocity control and particle dispersion than the gunpowder driven instrument. These improvements have increased cell viability, transformation efficiency, and cellular targets.

Air Pressure

The effects of two air-powder abrasive prophylaxis systems on the surface of machined titanium: a pilot study.

This in vitro pilot project compared the effect of two air-abrasive prophylaxis systems on the surface of machined titanium. Single Brånemark titanium abutment cylinders were exposed to the Prophy-Jet and Microprophy systems for 90 seconds each. Both of the test cylinders were compared with an untreated control cylinder by scanning electron microscopy. Machining marks were completely removed by the Prophy-Jet and only partially removed by the Microprophy. Both of the resultant surfaces appeared to be smoother and thus may be more resistant to plaque formation. A rationale for the removal of machining marks is presented, although the reason for the difference in removal by the two systems is unclear. The prophylaxis cleaning powders were also examined by scanning electron microscopy and exhibited similar particle dimensions and morphology. A noncrystalline deposit was observed on the surface of the abutment cylinder exposed to the Microprophy. Energy dispersive spectroscopy analysis revealed that the deposit consisted almost entirely of sodium. Further investigation of the deposit is needed.

Air Pressure

Detoxification of endotoxin-contaminated titanium and hydroxyapatite-coated surfaces utilizing various chemotherapeutic and mechanical modalities.

The surgical repair of the ailing implant may be complicated by the surface effects of pathogenic bacteria and their products. This study evaluated the ability of various chemotherapeutic modalities to detoxify endotoxin-contaminated titanium alloy and hydroxyapatite-coated test strips. Grit-blasted titanium alloy and hydroxyapatite-coated test strips were contaminated with purified outer membranes of Escherichia coli labeled with radioactive 14C. The titanium alloy strips were treated with citric acid, stannous fluoride, tetracycline HCl, chlorhexidine gluconate, hydrogen peroxide, chloramine T, sterile water, a plastic sonic scaler tip, and an air-powder abrasive unit. Hydroxyapatite-coated strips were treated with chloramine T, citric acid, or burnished with sterile water on cotton pellets. Residual lipopolysaccharide levels were measured by liquid scintillation spectrometry. The air-powder abrasive unit removed significantly greater amounts of lipopolysaccharide than all other treatment modalities on titanium samples (P < 0.05). A 60-second burnish with sterile water was able to remove significant amounts of lipopolysaccharide when compared with untreated controls (P < 0.05). Citric acid was superior in the removal of lipopolysaccharide from hydroxyapatite-coated surfaces when compared with the controls or chloramine T (P < 0.01). Detoxification of an implant infected surface may be beneficial when surgical repair of the ailing implant is indicated.

Air Pressure