PubMed HealthSearch

PubMed · 4093457

Flexor tenolysis.

Abstract

The results of thorough tenolysis of the flexor tendons in the palm and digits in selected patients can be quite gratifying. Preoperative requirements include a well-motivated patient with a supple digit and an established wide discrepancy between the active and passive ranges of digital motion. Careful preservation or reconstruction of annular pulleys and the demonstration of the adequacy of the lysis at the time of surgery are extremely important. A vigorous, protected, and closely monitored postoperative therapy course is critical to the success of the procedure. When this surgical-therapy program proceeds without complication, the improvement in digital flexion has been consistent, often with the restoration of near normal function. The incidence of tendon rupture, infection, or delayed wound healing has been low.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J W Strickland. 1985. Flexor tenolysis.. https://pubmed.ncbi.nlm.nih.gov/4093457/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of tension band wires in horses with fractures of the ulna: 22 cases (1980-1992).

Twenty-two horses with ulnar fractures were treated, using tension band wires alone or tension band wires in combination with pins or cortical bone screws. Age of the horses ranged from 2 weeks to 12 years (median, 4 months), and body weight ranged from 68 to 477 kg (median, 181 kg). Fractures were classified according to the Donecker and Bramlage ulnar fracture classification and included type 1-a (4 horses), type 1-b (4), type-2 (6), type-3 (1), type-4 (3), and type-5 (4), fractures. Tension band wires alone were used in 7 horses. Tension band wires were used in conjunction with unthreaded pins in 10 horses. In 3 horses, 5.5-mm cortical bone screws were inserted longitudinally instead of pins. A combination of a 5.5-mm cortical bone screw and a pin was used in 2 horses. In addition to pins and tension band wires, 4.5-mm cortical bone screws were placed in lag fashion to aid reduction of comminuted or oblique fractures in 7 of the 22 horses. Fractures healed in 18 (82%) horses. Four horses were euthanatized because of complications that included catastrophic failure of fixation during recovery from general anesthesia in 1 foal, septic arthritis and hyperextension of the contralateral metacarpophalangeal joint in 1 foal, and wound infection with partial disruption of repair in 2 horses. Nonfatal complications developed in 6 horses and included incision infection, partial wound dehiscence, carpal contraction, carpus varus of the contralateral forelimb, slight distraction of proximal fragments of the fractures, bent implants, and distal migration of pins. Long-term monitoring was performed on 17 horses.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, General