PubMed HealthSearch

PubMed · 4612795

Adherence to de-epithelized surfaces: a comparative study.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Tavis, J W Thornton, J H Harney, E A Woodroof, R H Bartlett. 1974. Adherence to de-epithelized surfaces: a comparative study.. https://pubmed.ncbi.nlm.nih.gov/4612795/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics.

This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurity-phases, and indices-of-crystallinity were used. In vitro testings were done by measuring the bonding-strength at the Ti-6Al-4V-HAC interface, with HACs that had and had not been immersed in a pH-buffered, serum-added simulated body fluid (SBF). The shear-strength at the HAC-bone interface was investigated in a canine transcortical femoral model after 12 and 24 weeks of implantation. The results showed a bonding degradation of approximately 32% or higher of the original strength after 4 weeks of immersion in SBF, and this predominantly depended on the constructed microstructure of the HACs. After the push-out measurements, it was demonstrated that the HACs with higher bonding-strength in vitro would correspondingly result in significantly higher shear-strength at each implant period in vivo. Nevertheless, there were no substantial histological variations between the two types of HACs evaluated. The most important point elucidated in this study was that, among coating characteristics, the microstructure was the key factor in influencing the mechanical stability of the HACs both in vitro and in vivo. As a consequence, a denser HAC was needed to ensure mechanical stability at both interfaces.

Adhesiveness

Fiber-matrix interface studies on bioabsorbable composite materials for internal fixation of bone fractures. I. Raw material evaluation and measurement of fiber-matrix interfacial adhesion.

The objective of this study was to characterize and evaluate the performance of various fiber-matrix composite systems by studying the mechanical, thermal, and physical properties of the fiber and matrix components, and by studying the fiber-matrix interface adhesion strength using both microbond and fragmentation methods. The composites studies were poly(L-lactic acid) (PLLA) matrix reinforced with continuous fibers of either nonabsorbable AS4 carbon (C), absorbable calcium phosphate (CaP), poly(glycolic acid) (PGA), or chitin. Carbon and CaP single fibers had high Young's moduli and failed in a brittle manner. PGA and chitin single fibers had relatively lower Young's moduli and relatively higher ductility. Upon in vitro hydrolysis, CaP fibers retained 17% of their tensile strength and 39% of their Young's modulus after 12 h, PCA fibers retained 10% of their tensile strength and 52% of their Young's modulus after 16 days, and chitin fibers retained 87% of their tensile strength and 130% of their Young's modulus after 25 days. PLLA films had much lower strength and Young's moduli, but much higher ductility relative to the single fibers. Using the microbond method, the initial fiber-matrix interfacial shear strength (IFSS) of C/PLLA and CaP/PLLA microcomposites was 33.9 and 12.6 MPa, respectively. Upon in vitro hydrolysis, C/PLLA retained 49% of IFSS after 15 days and CaP/PLLA retained 46% of IFSS after 6 h. Using a fiber fragmentation method, the initial IFSS of C/PLLA, CaP/PLLA, and chitin/ PLLA was 22.2, 15.6, and 28.3 MPa, respectively. The performance of carbon fibers and C/PLLA composites was superior to the other fibers and fiber/PLLA systems, but the carbon fiber was nonabsorbable. CaP had the most suitable modulus of the absorbable fibers for fixing cortical bone fracture, but its rapid deterioration of mechanical properties and loss of IFSS limits its use. PGA and chitin fibers had suitable mechanical properties and their retention for fixing cancellous bone fractures, but likely had insufficient stiffness for applications such as bone plates for fixing cortical bone fractures.

Adhesiveness

Patterned delivery of immunoglobulins to surfaces using microfluidic networks.

Microfluidic networks (microFNs) were used to pattern biomolecules with high resolution on a variety of substrates (gold, glass, or polystyrene). Elastomeric microFNs localized chemical reactions between the biomolecules and the surface, requiring only microliters of reagent to cover square millimeter-sized areas. The networks were designed to ensure stability and filling of the microFN and allowed a homogeneous distribution and robust attachment of material to the substrate along the conduits in the microFN. Immunoglobulins patterned on substrates by means of microFNs remained strictly confined to areas enclosed by the network with submicron resolution and were viable for subsequent use in assays. The approach is simple and general enough to suggest a practical way to incorporate biological material on technological substrates.

Adhesiveness