PubMed Health⌕ Search

PubMed · 475424

1028 neonatal electrocardiograms.

Abstract

Electrocardiograms were recorded from 1028 (99.4%) of 1034 consecutively born babies on the 1st or 2nd day of life. Abnormalities of cardiac rhythm or conduction were found in 49 (4.8%) babies. 17 babies had single or multiple premature beats during the recordings, and 7 babies showed sudden increases in R-R interval possibly due to sinoatrial node dysfunction. One baby had sinus or junctional bradycardia of less than 80 beats/min. One baby had an incessant reciprocating tachycardia and subsequently required digoxin for heart failure. Continuous 24-hour ECG monitoring in 25 babies with abnormalities of the screening ECG, and 25 babies without such abnormalities, failed to show any additional tachyarrhythmias or bradyarrhythmias warranting treatment. In view of the uncertain clinical significance of many neonatal arrhythmias and cardiac conduction disorders, more information concerning their natural history and relationship to sudden unexpected death in infancy is needed before recommending that neonatal ECG screening be generally adopted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R W Jones, C Sharp, L R Rabb, B R Lambert, D A Chamberlain. 1979. 1028 neonatal electrocardiograms.. https://doi.org/10.1136/adc.54.6.427

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Safety of nerve conduction studies in patients with implanted cardiac devices.

Patients with implanted cardiac devices and their physicians may defer important electrodiagnostic testing because of anxiety about potential negative effects on the device. To determine the safety of routine nerve conduction studies (NCS) in this population, 10 patients with permanent dual-chamber pacemakers of various types and five patients with implanted cardiac defibrillators (ICD) underwent nerve stimulation at sites commonly used during NCS. The implanted cardiac device was interrogated before and after the study and there was continuous monitoring of the surface electrocardiogram (ECG) and atrial and ventricular electrograms. Electrical impulses generated during routine NCS were never detected by the sensing amplifier and did not affect the programmed settings of the implanted cardiac device. We conclude that routine NCS is safe in patients with implanted cardiac pacemakers with bipolar sensing configurations and defibrillators.

Arrhythmias, Cardiac↗

[Pulmonary diseases and heart function].

The most severe cardiac sequel to lung disease is the load on the right ventricle due to pulmonary hypertension with the development of a cor pulmonale. This is characterized by hypertrophy and/or dilatation of the right ventricle because of a primary impairment of lung function and/or lung structure. The most important pathomechanisms for the development of pulmonary hypertension are vessel obliteration, mechanical lesions, primary vascular or extra-vascular inflammation and hypoxic vasoconstriction. Chronic obstructive pulmonary disease (COPD) is one of the most important reasons for chronic cor pulmonale. A further very common reason is obstructive sleep apnea syndrome, especially if combined with a COPD. In this case, the prevalence of cor pulmonale can reach 80%. The development of a chronic cor pulmonale is the most striking negative prognostic factor for these patients. Only 30% of COPD patients with cor pulmonale survive longer than 5 years, and only early detection of the disturbances to respiration which might potentially lead to cor pulmonale and their subsequent therapy are able to improve the patient's prognosis. Furthermore, pulmonary diseases may also have an impact on the left heart side in terms of an impairment of left heart function or by inducing severe arrhythmias . Thus, lung diseases may have both a significant impact on right and left heart performance.

Arrhythmias, Cardiac↗