PubMed Health⌕ Search

PubMed · 475492

Percutaneous jugular cannulation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Ellison, D R Jobes, A J Schwartz. 1979. Percutaneous jugular cannulation.. https://doi.org/10.1016/s0003-4975(10)63781-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Heart failure with a normal ejection fraction: is measurement of diastolic function necessary to make the diagnosis of diastolic heart failure?

BACKGROUND: The diagnosis of diastolic heart failure is generally made in patients who have the signs and symptoms of heart failure and a normal left ventricular (LV) ejection fraction. Whether the diagnosis also requires an objective measurement of parameters that reflect the diastolic properties of the ventricle has not been established. METHODS AND RESULTS: We hypothesized that the vast majority of patients with heart failure and a normal ejection fraction exhibit abnormal LV diastolic function. We tested this hypothesis by prospectively identifying 63 patients with a history of heart failure and an echocardiogram suggesting LV hypertrophy and a normal ejection fraction; we then assessed LV diastolic function during cardiac catheterization. All 63 patients had standard hemodynamic measurements; 47 underwent detailed micromanometer and echocardiographic-Doppler studies. The LV end-diastolic pressure was >16 mm Hg in 58 of the 63 patients; thus, 92% had elevated end-diastolic pressure (average, 24+/-8 mm Hg). The time constant of LV relaxation (average, 51+/-15 ms) was abnormal in 79% of the patients. The E/A ratio was abnormal in 48% of the patients. The E-wave deceleration time (average, 349+/-140 ms) was abnormal in 64% of the patients. One or more of the indexes of diastolic function were abnormal in every patient. CONCLUSIONS: Objective measurement of LV diastolic function serves to confirm rather than establish the diagnosis of diastolic heart failure. The diagnosis of diastolic heart failure can be made without the measurement of parameters that reflect LV diastolic function.

Cardiac Catheterization↗

Cardiac catheterization of low birth weight infants.

The increased survival of low birth weight infants means that more of these infants may be candidates for catheter interventions. There are few data on the results of cardiac catheterization in this group. This study aimed to analyze, retrospectively, cardiac catheterization of infants weighing < or =2.5 kg, with emphasis on the results of interventions. The complication rates of interventional and diagnostic procedures were compared. One hundred eleven catheterizations were performed in 107 patients between 1985 and 1998. Thirty-one procedures were interventional. Balloon atrial septostomy (n = 16), balloon pulmonary valvuloplasty (n = 10), balloon pulmonary angioplasty (n = 1), and coil occlusion of collateral vessels (n = 3) were all performed successfully. One infant (3%) died while undergoing myocardial biopsy. The reintervention rate for isolated pulmonary valve stenosis was 25% (2 of 8) at 1 month, 57% (4 of 7) at 6 months, and 71% (5 of 7) at 1 year. Complications were significantly more frequent during interventional (13 of 31, 42%) than during diagnostic (13 of 80, 16%) procedures. The most common complications during interventions were arrhythmias (3 of 31, 10%) and respiratory deterioration (3 of 31, 10%). Cardiac catheterization was technically feasible in all patients. Balloon pulmonary valvuloplasty and atrial septostomy provided good palliation in this patient group. The mortality of interventional procedures was low. The high incidence of respiratory complications suggests that low birth weight infants should undergo elective ventilation for interventional cardiac catheterization.

Cardiac Catheterization↗