PubMed Health⌕ Search

PubMed · 4887897

Cardiac output determination by digital computer: a simplified method.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T E Williams, R A Arcilla, M I Rowe, S R Deller, F J Lewis. 1968. Cardiac output determination by digital computer: a simplified method.. https://pubmed.ncbi.nlm.nih.gov/4887897/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

The aim of this study was to assess the feasibility of non-invasive determination of cardiac function from test-bolus data in multislice spiral computed tomography (MSCT). In 25 patients enhancement data gathered from a standardized test-bolus injection were analyzed. The test-bolus examination was performed prior to a retrospectively ECG-gated MSCT of the heart. A time-attenuation curve was obtained in the ascending aorta at the level of the pulmonary arteries. A gamma variate fit was applied to the curve in order to exclude recirculation and get pure first-pass data. Using the known amount of iodine injected, cardiac output (CO), and stroke volume (SV) were determined from integration of the fitted contrast enhancement curve using a reformation of the Stewart-Hamilton equation. Results were compared with CO and SV calculated from the geometric analysis of the retrospectively gated MSCT data using the ARGUS Software (Siemens, Forchheim, Germany). The CO and SV determined from test-bolus analysis and from geometric analysis correlated well with Pearson's correlation coefficients of 0.87 and 0.88, respectively. The standard deviation of the difference between both methods was 0.51 l/min for CO (8.6%) and 11.0 ml for SV (12.3%). Non-invasive quantification of CO seems to be feasible from a standard test-bolus injection. It provides valuable information on cardiac function without additional radiation or application of contrast material.

Cardiac Output↗

Modeling ventricular contraction with heart rate changes.

Recently, a mathematical model of the pumping heart has been proposed describing the heart as a pressure source depending on time, volume and flow. The underlying concept is based on a new two-step paradigm that allows separation between isovolumic (non-ejecting) and ejecting heart properties. The first step describes the ventricular pressure in the isovolumic ventricle. In the following step, the isovolumic description is extended with the ejection effect in order to embrace the pumping heart during actual blood ejection. The description of the isovolumic heart properties plays a crucial role in this paradigm. However, only a single isovolumic model has previously been used restricting the heart rate to 1 Hz. In this paper, a family of models describing the isovolumic contracting ventricle are critically examined. A characterization of what constitutes an optimal model is given and used as a criteria for choosing the optimal model in this family. Moreover, and this is indeed a point, the proposed model in this study is valid for arbitrary heart rates and based on experimental data. The model exhibits all major features of the ejecting heart, including how ventricular pressure and flow vary in time for various heart rates and how stroke volume and cardiac output vary with heart rate. The modeling strategy presented embraces the same steps and demarcations as those suitable for clinical examination whereby new experiments are suggested.

Cardiac Output↗