PubMed Health⌕ Search

PubMed · 5019504

A multi-bin EKG counter.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Reus, W P Paré. A multi-bin EKG counter.. https://doi.org/10.1007/bf03000482

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Early resolution of ST-segment elevation correlates with myocardial salvage assessed by Tc-99m sestamibi scintigraphy in patients with acute myocardial infarction after mechanical or thrombolytic reperfusion therapy.

BACKGROUND: Early resolution of ST-segment elevation is an indicator of final infarct size and clinical outcomes. Whether this correlation is an expression of initial infarct characteristics or degree of myocardial salvage achieved with reperfusion therapy is unclear. METHODS AND RESULTS: We prospectively included 243 patients with acute myocardial infarction (AMI) treated with either coronary stenting (122 patients) or thrombolysis (121 patients). Serial 12-lead electrocardiograms (ECG) were performed at baseline and 90 minutes after initiation of therapy. ST-segment resolution was defined as complete (> or =70%), partial (<70% to 30%), or no resolution (<30%). Paired technetium-99m sestamibi scintigraphic studies were performed to calculate the initial perfusion defect, final infarct size, and the proportion of initial defect salvaged with reperfusion (salvage index). ST-segment resolution correlated significantly with salvage index (P=0.008), final infarct size (P<0.001), and 6-month mortality (P=0.03). In the groups with complete, partial, and no resolution, salvage index was 0.54+/-0.32, 0.39+/-0.36, and 0.33+/-0.60; final infarct size was 12.5+/-12.0%, 20.0+/-13.9%, and 22.7+/-19.4% of the left ventricle; 6-month mortality was 2.4%, 6.2%, and 12.8%, respectively. After adjustment for baseline characteristics, ST-segment resolution was the second strongest predictor of salvage index (P=0.007) after the type of reperfusion, stenting, or thrombolysis (P=0.001); it was greater after stenting than after thrombolysis (P<0.001). CONCLUSION: Early resolution of ST-segment elevation in surface ECG correlates with myocardial salvage as assessed by scintigraphy in patients with AMI after reperfusion therapy. These data provide an explanation for the favorable prognostic value of the ST-segment resolution and support the use of this parameter to compare the efficacy of different reperfusion strategies.

Electrocardiography↗

Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis.

OBJECTIVES: The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). BACKGROUND: Several comparisons of ECG-gated SPECT with cardiac MRI have been performed for evaluation of LV volumes and EF, but each has considered few subjects, thus leaving uncertainty about the frequency of discrepancies between the two methods. METHODS: We performed a meta-analysis of data on 164 subjects from nine studies comparing ECG-gated SPECT versus cardiac MRI. Data were pooled in correlation and regression analyses relating ECG-gated SPECT and cardiac MRI measurements. The frequency of discrepancies of at least 30 ml in EDV, 20 ml in ESV and 5% or 10% in EF and concordance for EF < or =40% versus >40% were determined. RESULTS: There was an overall excellent correlation between ECG-gated SPECT and cardiac MRI for EDV (r = 0.89), ESV (r = 0.92) and EF (r = 0.87). However, rates of discrepancies for individual subjects were considerable (37% [95% confidence interval [CI], 26% to 50%] for at least 30 ml in EDV; 35% [95% CI, 23% to 49%] for at least 20 ml in ESV; 52% [95% CI, 37% to 63%] for at least 5% in EF; and 23% [95% CI, 11% to 42%] for at least 10% in EF). The misclassification rate for the 40% EF cutoff was 11%. CONCLUSIONS: Electrocardiogram-gated SPECT measurements of EDV, ESV and EF show high correlation with cardiac MRI measurements, but substantial errors may occur in individual patients. Electrocardiogram-gated SPECT offers useful functional information, but cardiac MRI should be used when accurate measurement is required.

Electrocardiography↗