PubMed Health⌕ Search

PubMed · 509971

A physiological approach to hemidiaphragm paralysis.

Abstract

The occurrence of unilateral phrenic nerve injury with the resultant hemidiaphragm paralysis or paresis can cause significant respiratory distress or respiratory failure in infants and children. An early bedside diagnosis of this problem will allow appropriate therapy and prevent needless diagnostic procedures. With the patient in the lateral decubitus position and the paralyzed side up, accentuated paradoxical inspiratory inward epigastric motion ipsilateral to the paralyzed hemidiaphragm can be seen. With the paralyzed hemidiaphragm down, abdominal motion appears to be normal as if the paralyzed hemidiaphragm were plicated. Thus, ventilation may be improved by changing body position as well as instituting ventilatory support while the potential for phrenic nerve recovery is evaluated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Robotham. 1979. A physiological approach to hemidiaphragm paralysis.. https://doi.org/10.1097/00003246-197912000-00012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT.

PURPOSE: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. METHODS AND MATERIALS: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). RESULTS: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. CONCLUSION: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

Diaphragm↗

Brief review: Neuromuscular monitoring: an update for the clinician.

PURPOSE: To review established techniques and to provide an update on new methods for clinical monitoring of neuromuscular function relevant to anesthesia. SOURCE: A PubMed search of relevant article for the period 1985-2005 was undertaken, and bibliographies were scanned for additional sources. PRINCIPAL FINDINGS: There is no substitute for objective neuromuscular monitoring; for research purposes, mechanomyography (MMG) is the gold standard; however, the most versatile method in the clinical setting is acceleromyography since it can be applied at various muscles and has a long track record of clinical utility. Kinemyography is valid to monitor recovery of neuromuscular transmission at the adductor pollicis muscle (AP), whereas phonomyography is easy to apply to various muscles and shows promising agreement with MMG. Monitoring of the corrugator supercilii muscle (CS) may be used to determine the earliest time for tracheal intubation as it reflects laryngeal relaxation better than monitoring at the AP. Recovery of neuromuscular transmission is best monitored at the AP, since it is the last muscle to recover from neuromuscular blockade (NMB). If train-of-four (TOF) stimulation is used, a TOF-ratio > 0.9 should be the target before awakening the patient. If surgery or the type of anesthesia necessitates NMB of a certain degree, e.g., TOF-ratio = 0.25, monitoring of muscles which best reflect the degree of NMB at the surgical site is preferable. CONCLUSION: Objective methods should be used to monitor neuromuscular function in clinical anesthesia. Acceleromyography offers the best compromise with respect to ease of use, practicality, versatility, precision and applicability at various muscles. The CS is the optimal muscle to determine the earliest time for intubation, e.g., for rapid sequence induction.

Diaphragm↗