Measuring ventricular extrasystoles.

Abstract

Uniform ventricular extrasystoles can be divided into three types: fixed coupling, parasystole, and variable non-parasystolic coupling. Frequency distributions of coupling intervals of ventricular extrasystoles were determined from long electrocardiographic recordings of 51 patients with variable coupling. These distributions were of five types: (a) two distinct coupling intervals, (b) a preponderance of extrasystoles with short coupling intervals and less frequent extrasystoles with progressively longer coupling, (c) a preponderance of long coupling intervals and less frequent extrasystoles with progressively shorter coupling, (d) an even distribution and (3) a central distribution. Interectopic intervals were measured in these electrocardiograms (ECGs). Parasystole was found only in three recordings. It is recommended that the diagnosis of parasystole be made only if the degree of variation of the ectopic cycle (both when it is manifest and when it is concealed) is less than the variation of the coupling intervals. When the ECGs with variable non-parasystolic coupling were compared with 44 ECGs with fixed coupling, it was found that variable coupling was associated with abnormalities of the basic electrocardiographic contour, multiformity of extrasystoles and repetitive extrasystoles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Talbot. 1975. Measuring ventricular extrasystoles.. https://doi.org/10.1016/s0022-0736(75)80005-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[CME-ECG 2].

Explore the source record for details and available documents.

Cardiac Complexes, Premature↗

Extrasystoles: side effect of kangaroo care?

OBJECTIVE: To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. DESIGN: Case report. PATIENT: Preterm infant. MEASUREMENTS AND MAIN RESULTS: A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. CONCLUSIONS: ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

Cardiac Complexes, Premature↗