High-level gamma-ray dosimetry using common TLD phosphors.

Abstract

Thermoluminescence of high temperature peaks, ultraviolet radiation (253.7 nm) induced thermoluminescence and phosphorescence, damage effects and optical density changes in a few common TLD phosphors namely CaSO4 : Tm, CaSO4 : Dy, LiF TLD-100 and Li2B4O7 : Mn were studied from the point of view of measuring high level gamma doses (10(2)--10(6) Gy).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A R Lakshmanan, R C Bhatt. 1979. High-level gamma-ray dosimetry using common TLD phosphors.. https://doi.org/10.1088/0031-9155%2F24%2F6%2F016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Self-assembling poly(dioxaborole)s as blue-emissive materials.

Conjugated, borole-linked polymers have been self-assembled based on boronate ester formation between a fluorene-2,7-diboronic acid and 1,2,4,5-tetrahydroxybenzene. Readily soluble polymers with molecular weights approaching 60 000 have been generated with materials exhibiting extended conjugation over approximately 3-5 borole linkages. Emission from these polymers reaches into the visible (blue) range, representing a novel class of blue-emitting materials.

Borates↗

Application of ionic liquids in the microwave-assisted extraction of trans-resveratrol from Rhizma Polygoni Cuspidati.

In this paper, the application of 1-n-butyl -3-methylimidazolium-based ionic liquids aqueous solutions as solvents in the microwave-assisted extraction (MAE) technique was first developed for the extraction of trans-resveratrol from Rhizma Polygoni Cuspidati. 1-butyl-3-methylimidazolium bromide ([bmim]Br) solution was selected as solvent; the conditions of MAE including the size of sample, liquid/solid ratio, extraction temperature and time were optimized by means of an orthogonal design L(9)(3(4)). Under optimized conditions, the extraction yield value of trans-resveratrol was 92.8% in a one-step extraction. The recovery was in the range 93.7-103.2% with relative standard deviation lower than 3.0% by the proposed procedure. The method was applied to extract trans-resveratrol from several different region samples. On the basis of extraction solvent and time, the proposed extraction technique was a green, rapid and alternative technique to extract and analyze trans-resveratrol in Rhizma Polygoni Cuspidati samples.

Borates↗