PubMed HealthSearch

PubMed · 5484921

Oestriol in amniotic fluid.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Klopper. 1970. Oestriol in amniotic fluid.. https://pubmed.ncbi.nlm.nih.gov/5484921/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Elevations of amniotic fluid macrophage inflammatory protein-1 alpha concentrations in women during term and preterm labor.

OBJECTIVE: To determine whether elevated concentrations of macrophage inflammatory protein-1 alpha (MIP-1 alpha) in amniotic fluid (AF) are related to term and preterm labor. METHODS: Amniotic fluid was obtained from women from five different clinical situations: 1) term cesarean delivery, no labor (n = 29); 2) normal term labor, no infection (n = 36); 3) preterm labor, delivery more than 1 week from sampling, no infection (n = 19); 4) preterm labor, delivery within 1 week from sampling, no infection (n = 18); and 5) preterm chorioamnionitis (n = 8). Amniotic fluid was collected aseptically at the time of amniocentesis, amniotomy, or hysterotomy. Concentrations of MIP-1 alpha were determined by enzyme-linked immunosorbent assay. Statistical analysis was by Wilcoxon rank-sum test, Kruskal-Wallis test, and unpaired t test. RESULTS: Women in normal term labor had significant elevations of AF MIP-1 alpha concentrations when compared with women at term undergoing repeat cesarean delivery (P < .001). In women with term gestation, AF MIP-1 alpha correlated well with cervical dilation (r2 = 0.479, P < .001). In women with preterm labor who later delivered within 1 week of presentation, AF MIP-1 alpha concentrations were higher than those from women who did not deliver within 1 week. Women who presented with clinically evident chorioamnionitis had the highest concentrations of AF MIP-1 alpha (P = .001). CONCLUSION: Women in labor have significantly elevated AF concentrations of MIP-1 alpha, particularly if labor is associated with intrauterine infection. We suggest that MIP-1 alpha is involved in the physiology of normal labor and in the pathogenesis of infection-associated preterm labor.

Amniotic Fluid

Prognostic significance of unexplained elevated amniotic fluid alpha-fetoprotein.

OBJECTIVE: To compare the prognostic values of unexplained elevated amniotic fluid alpha-fetoprotein (AF AFP > or = 2.0 multiples of the median [MoM]) and unexplained elevated maternal serum alpha-fetoprotein (MSAFP > or = 2.5 MoM). METHODS: We accessed a data base containing the results of MSAFP screening tests, genetic amniocenteses, and pregnancy outcome data on all women undergoing second-trimester genetic amniocentesis from October 1988 through August 1994. After excluding all patients whose elevated AFP levels had any identifiable cause (positive AF acetylcholinesterase, AF blood contamination, fetal malformation or aneuploidy, multiple gestation, etc), 5743 cases were analyzed. Relative risks (RR) for selected pregnancy complications were determined. RESULTS: Elevated MSAFP, with any AF AFP, was associated with fetal growth restriction (RR 2.5, 95% confidence interval [CI] 1.4-4.4), stillbirth (RR 3.5, 95% CI 1.4-8.3), preeclampsia (RR 2.8, 95% CI 1.1-7.0), and preterm delivery (RR 2.8, 95% CI 2.3-3.4). Elevated AF AFP, with any MSAFP, was associated with preeclampsia (RR 4.4, 95% CI 2.0-10.0) and preterm delivery (RR 1.7, 95% CI 1.3-2.4). Elevation of both AF AFP and MSAFP was associated with preterm delivery (RR 4.0, 95% CI 2.8-5.7). When elevated AF AFP was found in association with a normal MSAFP, the RR to develop preeclampsia was 4.6 (95% CI 1.9-11.2). CONCLUSION: Maternal serum alpha-fetoprotein is a better predictor of late pregnancy complications than AF AFP. However, unexplained elevated AF AFP appears to be especially predictive of preeclampsia.

Amniotic Fluid

How frequently should the amniotic fluid index be performed during the course of antepartum testing?

OBJECTIVE: Our purpose was to evaluate the need for frequent amniotic fluid volume assessments in our antepartum testing unit. STUDY DESIGN: In a retrospective analysis of data accumulated over 1 year in our antepartum testing unit amniotic fluid index values performed at 3- to 4-day intervals were compared with follow-up values. Of 11,827 amniotic fluid index values, there were 6291 with follow-up values within 4 days. The results were stratified on the basis of the subsequent amniotic fluid index value and estimated gestational age. Comparisons were made relating to amniotic fluid index testing intervals of 4 versus 7 days. RESULTS: Patients with an amniotic fluid index > 8 cm had a 2.3% chance (128/5677) of having oligohydramnios (amniotic fluid index < or = 5.0 cm) in the next 4 days. Those patients with low-normal amniotic fluid index values (5 to 8 cm) had a 16.2% chance (96/593) of having oligohydramnios in the next 4 days. There were few patients with an amniotic fluid index < or = 5 cm who had subsequent amniotic fluid index values measured. Patients with an amniotic fluid index > 8 cm had a 2.2% chance (156/6946) of having oligohydramnios within 7 days, and those with low-normal amniotic fluid index values had a 16.3% chance (105/643) of having oligohydramnios with 7 days. Stratifying the results by gestational age reveals that patients at > or = 41 weeks of gestation had a 23.3% chance of having oligohydramnios within 4 days if the current amniotic fluid index was found to be 5 to 8 cm and a 7.4% chance if the current amniotic fluid index was found to be normal. Term (estimated gestational age of 37 to 40 weeks) patients had a similar risk of oligohydramnios in 4 days if the amniotic fluid index was low-normal (17.8%) but a risk of 3.6% if the amniotic fluid index was normal. CONCLUSIONS: For patients at < 41 weeks of gestation undergoing antepartum testing, weekly assessments of amniotic fluid index is probably adequate if the initial measurement is in the normal range (> or = 8 cm) because the risk of having oligohydramnios within 7 days is low (2.2%). For patients at < 41 weeks of gestation whose initial amniotic fluid index measurement is in the low-normal range (5 to 8 cm), a scheme of twice-weekly assessment is justified on the basis of a higher risk for an amniotic fluid index < or = 5 cm within 4 days (12.3%). For all patients at > or = 41 weeks of gestation, twice-weekly amniotic fluid index assessments are recommended regardless of the initial measurement.

Amniotic Fluid