PubMed HealthSearch

PubMed · 5487672

A joint simulating machine for load-bearing joints.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Dowson, P S Walker, M D Longfield, V Wright. 1970. A joint simulating machine for load-bearing joints.. https://doi.org/10.1007/bf02551747

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prosthesis displacement as a complication of reduction of a dislocated total hip arthroplasty.

Acute displacement at the cement-prosthesis interface of the femoral component of a hip arthroplasty that occurred as a consequence of attempted reduction of a dislocation is described. Although this complication is theoretically possible with a polished tapered stem design, it is previously unrecognized, and may be avoidable if fluoroscopic control is used during closed reduction of a dislocation.

Hip Joint

From the RSNA refresher courses. Total hip arthroplasty: radiographic evaluation.

Expected appearances of total hip arthroplasty vary according to type of implant, its method of fixation (cemented, porous coating for bone ingrowth, press fit), and whether it is a revision. Cemented arthroplastic components normally may show 1-2-mm-wide radiolucent zones at cement interfaces. Definite loosening is diagnosed when progressive widening of the radiolucent zone, migration of a cemented component, or change in alignment is seen. In cementless arthroplasty, normal findings include calcar resorption, radiolucent zones up to 2 mm in width, cortical thickening, periosteal reaction, endosteal sclerosis, and even subsidence of the femoral component that stabilizes at less than 1 cm. The most reliable radiographic signs of loosening in cementless arthroplasty are progressive subsidence, migration, or tilt of the component. Because subsidence or change in alignment may be very subtle, serial radiography and measurement are often required for diagnosis. Other signs that indicate loosening include bead shedding (in porous-coated prostheses), extensive cortical hypertrophy, endosteal bone bridging at the stem tip, endosteal scalloping, and a radiolucent zone wider than 2 mm. In revision arthroplasty, wide radiolucent zones and subsidence are common. The diagnosis of revision failure is based on progressive widening of the radiolucent zones and change in component position after 12 months.

Hip Joint