Temporal effects in the estimation of pulmonary diffusing capacity.

Abstract

Steady state estimates of the pulmonary diffusing capacity for carbon monoxide (DLCO) require measurement of the uptake and the average alveolar partial pressure of carbon monoxide (PACO). The expired alveolar sample obtained by different experimental methods and/or breathing patterns rarely represents the actual PACO. It is widely accepted that nonuniform distribution of ventilation, diffusion and perfusion causes discrepancies in the measurement of diffusing capacity. tan additional source of error in choosing PACO arises in the sampling time chosen by the experimental method. A theoretical study of a ramp-with-pause and a square breathing pattern demonstrates that the sample-time error exists even in the homogeneous lung. The study shows for the homogeneous lung that the correct fractional concentration of alveolar carbon monoxide (FAV) occurs at a time (TAV), one-half of a breathing period after the effective inspiration time (TI) for the two very different breathing patterns. TI is well-defined in relation to any breathing pattern which can be approximated by ramps and pauses. If TAV and the sample time chosen by the experimental method are known, then the measured DLCO can be corrected to the actual diffusing capacity (DL). The theory agrees with experimental results and computer simulations of inhomogeneous lungs from the literature. This agreement suggests that the theory for the homogeneous lung is also relevant to the inhomogeneous lung.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N B Kindig, D R Hazlett. 1977. Temporal effects in the estimation of pulmonary diffusing capacity.. https://doi.org/10.1113/expphysiol.1977.sp002382

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Carbon monoxide-driven proton respiration enables facultative anaerobes to survive electron acceptor limitation.

Diverse microorganisms couple the oxidation of carbon monoxide gas (CO) to the reduction of protons, producing hydrogen gas (H2) using nickel-containing CO dehydrogenase/energy-converting hydrogenase (Ni-CODH/ECH). Although this process yields one of the lowest free-energy gains in biology, its physiological role at environmentally relevant CO levels remains unresolved. Here, we show that Ni-CODH/ECH functions as a survival-oriented energy conservation system that enables heterotrophic facultative anaerobes to survive electron acceptor limitation, rather than primarily supporting growth or CO detoxification. Analysis of 387 genomes of Anoxybacillaceae species revealed that Ni-CODH/ECH had a patchy distribution and, with one exception, was mutually exclusive with the oxygen-tolerant molybdenum-containing CODH, suggesting ecological specialization. Culture experiments using three isolates (Parageobacillus sp. G301, P. thermoglucosidasius NBRC 107763, and Thermolongibacillus altinsuensis B1-1) demonstrated that CO-dependent proton respiration is activated during stationary phase when exogenous electron acceptors are limiting, maintaining cell density under 25% CO, whereas no effect was observed in a Ni-CODH knockout (ΔcooCSF) strain. RNA-seq analysis of Parageobacillus sp. G301 under twelve conditions revealed that Ni-CODH/ECH genes are highly expressed (top 0.2%-1.9% of all genes) under electron acceptor-free conditions, independent of CO presence, under the predicted control of the redox-dependent transcriptional repressor Rex. ΔcooCSF cultures accumulated more CO than the wild-type (WT), suggesting trace CO scavenging by the WT. Together, our results redefine Ni-CODH/ECH as a redox-regulated auxiliary energy-conservation strategy that supports survival and maintenance in anaerobic energy-limited environments using two ubiquitous substrates. This work extends the carboxydovore paradigm of trace gas-based survival from aerobic to spatiotemporally variable anaerobic environments.

Carbon Monoxide↗

Organometallics meet colloid chemistry: a case study in three phases based on molecular carbonyl precursors containing zinc and manganese.

Two organometallic compounds containing zinc and manganese in different ratios are used as single-source precursors for the preparation of various new, bimetallic oxide materials with nanoscaled dimensions. It is shown that the materials synthesis can be performed in the solid-state, the liquid-phase, and even in the gas-phase. The molecular composition of the precursors determines the composition of the resulting materials. In addition, two novel methods for the preparation of highly crystalline metal oxide colloids are presented: The coupling between a gas-phase process and a colloidal approach, and the application of ozone as an oxidant for the transformation of metal carbonyls into oxides in the liquid phase.

Carbon Monoxide↗

Microfluidic flow-flash: method for investigating protein dynamics.

We report a new method, microfluidic flow-flash, for measuring protein reaction kinetics. The method couples a microscope imaging detection system with a microfluidic flow cell to reduce data acquisition times and sample consumption. This combination allows for the simultaneous collection of spectral and temporal information. The microfluidic flow cell design utilizes three-dimensional sheath flow to reduce sample dispersion and minimize sample consumption. The ability to alter the flow rates in the microfluidic flow cells allows a variety of time scales to be studied with submillisecond time resolution. The imaging detection system can be coupled with several spectroscopic probes including fluorescence and UV/visible absorbance spectroscopy. Here, we utilize the microfluidic flow-flash method to probe the kinetics of CO recombination or O2 binding to myoglobin after the laser-induced photolysis of CO from myoglobin by UV/visible absorbance spectral imaging.

Carbon Monoxide↗