PubMed HealthSearch

PubMed · 5908012

Increased oestrogen activity associated with postmenopausal bleeding.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Frampton. 1966. Increased oestrogen activity associated with postmenopausal bleeding.. https://doi.org/10.1111/j.1471-0528.1966.tb05132.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From biochemical to biophysical placental function tests in fetal surveillance.

Radioimmunoassays of human placental lactogen and estriol levels in the maternal plasma, ultrasound biometry of the abdominal diameter (AD), pulsed Doppler measurements of uteroplacental arteries, the common carotid artery (CCA), and the umbilical artery (UA) and fetal heart rate monitoring were simultaneously performed in 219 risk pregnancies from 26 weeks' onward at regular intervals. The prognostic value of all tests to predict small for gestational age infants (SGA) and fetal distress was evaluated simultaneously. Receiver operator characteristic allowed the simultaneous comparison of all methods: The AD was most predictive for early detection of SGA, even more than uteroplacental blood flow. Fetal blood flow redistribution expressed as a ratio of the resistance index of CCA/UA was the most significant test for detection of fetal distress later in pregnancy, even more than antenatal cardiotocography. Considering cutoff levels used in clinical routine, the sensitivity and specificity of the fetal AD in detecting intrauterine growth retardation more than 28 days before birth, were 71 and 81%, respectively. Pulsed Doppler measurements of CCA/UA less than 7 days before the delivery had a sensitivity and specificity of 83 and 90%, respectively. Our results demonstrate the historical change in fetal surveillance within one study group: If accurate routine ultrasound is available, the use of biochemical placental function tests is not justified, a procedure that is already accepted in nearly all perinatal centers. Fetal cerebral versus umbilical blood flow measurements should be applied as a tool to measure fetal blood flow redistribution in small fetuses to predict most precisely the risk for poor outcome and perinatal hypoxia.

Estriol

The biochemistry and clinical application of urinary oestriol measurement during late pregnancy in the 1990's.

Part 1. The present disillusionment with oestriol measurement as a test of fetoplacental function could be explained by the use of poor methodology and inappropriate normal ranges rather than that the test has lost its usefulness. We have updated the Lever method for measuring oestriol in urine, and examined the automatic TDX system supplied by Abbott Laboratories. The precision of the methods and consistency of results between methods have been determined and normal ranges have been established for both methods. The overall accuracy of collection of 24-hour urine specimens in a routine laboratory setting has also been calculated. The normal ranges suggested as a guide for the TDX method by Abbott were based on those derived from the original method of Brown and were found to be too low and therefore unsuitable for clinical use. This study reports appropriate lower limits of normal for both the updated Lever and the TDX methods. Part 2. The results obtained using the updated Lever method since its introduction in 1991 have been compared with those obtained by the original Brown method during the years 1971-1989. The new, user-friendly Lever method of oestriol assay measurement used in 1991-1993 gave results of equivalent clinical value to the Brown method used in 1971-1989, although the perinatal mortality rates in the tested populations fell from 0.95% to 0.37%. During 1971-1989, low oestriol excretion on 1 or more occasions was associated with a 5.6-fold increase in the perinatal mortality rate (0.66% to 3.67%), whereas in 1991-1993, the factor was 4.4 (0.27% to 1.2%).(ABSTRACT TRUNCATED AT 250 WORDS)

Estriol