PubMed Health⌕ Search

PubMed · 6034276

The translator.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L G Welt. 1967. The translator.. https://pubmed.ncbi.nlm.nih.gov/6034276/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LIFEdb: a database for functional genomics experiments integrating information from external sources, and serving as a sample tracking system.

We have implemented LIFEdb (http://www.dkfz.de/LIFEdb) to link information regarding novel human full-length cDNAs generated and sequenced by the German cDNA Consortium with functional information on the encoded proteins produced in functional genomics and proteomics approaches. The database also serves as a sample-tracking system to manage the process from cDNA to experimental read-out and data interpretation. A web interface enables the scientific community to explore and visualize features of the annotated cDNAs and ORFs combined with experimental results, and thus helps to unravel new features of proteins with as yet unknown functions.

Automation↗

Automatic quantification of gene amplification in clinical samples by IQ-FISH.

BACKGROUND: The reliable detection and quantification of gene amplifications is crucial to clinical practice. Although there are different detection techniques, the fluorescence in situ hybridization (FISH) method has become highly accepted over past years because it is a reliable, robust, and quick method. Unfortunately, automatic quantification of gene amplification based on fluorescence intensities has not been possible thus far. Because current spot counting methods are reliable only when analyzing low amplification rates, we attempted to establish another method, i.e., to quantify the intensity of different FISH signals using an automatic fluorescence microscopical device on interphase nuclei: interphase quantitative FISH (IQ-FISH). METHODS: We quantified the fluorescence intensities of the differently labeled FISH probes (MYCN and D2Z) hybridized to three different neuroblastoma cell lines, six peripheral blood (PB) samples, 10 spiked PB samples, and nine neuroblastoma samples using the Metafer4 system (MetaSystems, Altlussheim, Germany). To obtain the MYCN copy number per cell, the ratio between the fluorescence intensities of the MYCN gene and reference sequence (D2Z) was calculated. For automatic analysis of the HER-2/neu status in tumor cells, labeled FISH probes specific for HER-2/neu and a chromosome 17-specific probe were hybridized to peripheral blood and tumor specimens and analyzed using the automatic device. RESULTS: When measuring the fluorescence intensity per cell for both probe pairs (MYCN/D2Z and HER-2/17p), amplified and non-amplified cells, showed distinct peaks with only little overlap. Whereas normal cells showed a fluorescence ratio peak for MYCN/D2Z between 200 and 800, cells with MYCN amplification clearly exceeded this ratio value (1000 to 25,000). When mixing a varying number of MYCN amplified cells (range 9-91%) to normal PB, the spiked tumor cells could be identified. Even one neuroblastoma tumor cell in 1000 mononucleated cells could reliably be detected using our device. In neuroblastoma patient samples, non-amplified cells were distinguished from amplified cells. Automatically and manually counted signals gave matching results in amplified and non-amplified samples. HER-2/neu-amplified cells were automatically detected in the breast cancer samples analyzed. CONCLUSION: The automatic measurement of fluorescence signal intensities not only allows a reliable discrimination between non-amplified and amplified cells but also exact quantification of amplified sequences. This is the prerequisite for the following applications: detection of amplified cells in the bone marrow and second-look specimens; comparison between primary and relapse or pre- and post-chemotherapeutic specimens; detection of tumors with focal gene amplification; and quantification of elimination of amplified gene sequences.

Automation↗

Quantitation of hepatitis B surface antigen by an automated chemiluminescent microparticle immunoassay.

A fully automated chemiluminescent microparticle immunoassay (Architect HBsAg QT) was used for the detection and quantitation of hepatitis B surface antigen (HBsAg). The assay is capable of processing up to 800 HBsAg tests per hour. The concentration of HBsAg is determined by utilizing a previously generated Architect HBsAg calibration curve. Architect HBsAg QT sensitivity was found to be around 0.2ng/ml which is equivalent or superior to other known and commercially available enzyme immunoassays and/or chemiluminescent immunoassays. We performed a quantitative study of HBsAg, HBeAg, HBV-DNA and HBV-DNA polymerase in over 733 sera obtained from 43 chronic hepatitis B carriers. Serum HBsAg levels detected by Architect HBsAg QT were found to be higher in HBeAg-positive than in anti-HBe-positive HBV chronic carriers and correlated with the level of serum HBV-DNA and HBV-DNA polymerase.

Automation↗