PubMed HealthSearch

PubMed · 615508

[Analysis of plasma urea by continuous flow method using enzymes].

Abstract

An automated continuous flow method is described for the assay of plasmatic urea after hydrolysis by urease followed by NH+4 assay with glutamic-deshydrogenase. Precision and accuracy, comparison with chimical diacetyl-monoxim method are studied. The interaction of endogenous NH+4, the cost of the method are calculated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Lustenberger, J L Orsonneau, G Cornu, S Bernard. 1977. [Analysis of plasma urea by continuous flow method using enzymes].. https://pubmed.ncbi.nlm.nih.gov/615508/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

pO2-profiles in human muscle tissue as indicator of therapeutical effect in septic shock patients.

Automatically stepwise driven pO2 electrodes were transcutaneously inserted into muscle tissue of severely ill septic shock patients. The pO2 profile was plotted from 200 individual measurements registered during 5 minutes and a histogram plotted for documentation. Arterial and venous blood gases, cardiac output, systemic and pulmonary vascular resistance were measured continuously on-line. In septicemia multiple drug schemes are suggested all intending to increase oxygen supply to the tissue and to improve oxygen demand/supply mismatch. So far the attending physician is bound to conclude and continue respectively change the treatment scheme according to the above described macrophysiological parameters. Perfusion distribution and local inhomogenities of tissue oxygen supply remain undetected. In the described study pretreatment pO2 profiles in musculus quadriceps femoris were obtained and measurements repeated in intervals of 10 minutes after start of pharmacological treatment. The changes of pO2 profiles of 20 patients, monitored in such a way over days and weeks, were carefully correlated to the described cardiocirculatory parameters and blood gas analyses. Dopamine was used to improve cardiac function and tissue oxygen supply as well. The investigations show that resulting changes of cardiovascular and blood gas parameters do not always indicate that tissue oxygen supply has really improved. On the other hand there was never an improvement in tissue oxygen supply when no changes of the other parameters had occurred. It is advised to add as a further diagnostic parameter tissue pO2 measurements to get insight if improvement in cardiac and pulmonary function really has the intended effect of improvement of tissue oxygen supply.

Autoanalysis

Direct automated sequencing of 16S rDNA amplified by polymerase chain reaction from bacterial cultures without DNA purification.

The 16S rRNA gene from various bacterial cultures was amplified by the polymerase chain reaction without DNA purification, and sequenced directly by using a laser fluorescent DNA sequencer and Tth polymerase with a cycle sequencing protocol. The described procedures provide almost complete 16S rDNA sequence data within a couple of days and facilitate systematic studies.

Autoanalysis

Glycated haemoglobin: an assessment of high capacity liquid chromatographic and immunoassay methods.

We have assessed five high-throughput systems for the measurement of glycated haemoglobin and have reviewed published evaluations of individual analysers. All systems offered better precision than a widely used electroendosmosis method. The low pressure chromatography and immunoassay systems demonstrated greater between-batch imprecision than the high performance liquid chromatography analysers, the latter achieving the proposed analytical goal of between-batch coefficients of variation less than 5%. Agreement between all systems measuring HbA1 was good but there was variability amongst observed HbA1c values. The systems were also assessed for their quality of chromatographic separation, simplicity of operation, flexibility, cost and potential for interference by other haemoglobins.

Autoanalysis