PubMed Health⌕ Search

PubMed · 6170764

[Clinical rhinomanometry].

Abstract

Between 1971 and 1978 the author did 575 rhinomanometric examinations, using the Cottle rhinomanometer, Model FP-102. It was always a unilateral passive rhinomanometry. Results obtained on the rhinomanometer were compared with the patient's history and the clinical examination. For 423 cases (74%) the rhinomanometry confirmed the clinical data, and for 152 cases (26%) there was no relation between the two. It is concluded that for evaluation and choice of treatment the clinical history and examination are the only valuable criteria. Defects of the rhinomanometer are discussed. In medical rhinitis an effect was noticed which was exactly the contrary to that expected with a local decongestant. We believe that this equipment is not sufficiently developed to be currently useful in clinical work although rhinomanometry may have a role in research.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Czernic. 1981. [Clinical rhinomanometry].. https://pubmed.ncbi.nlm.nih.gov/6170764/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗