PubMed HealthSearch

PubMed · 6375997

Estimation of sampling errors in a high-resolution TV microscope image-processing system.

Abstract

The basic postulate of this paper is that the commonly accepted sampling density of 2-4 pixels/micron in a high-resolution TV microscope system is too low to digitize exactly and analyze the complex cellular detail found in stained cell images. Depending on the specific microscope system, the required sampling density is much higher, lying between 15 and 30 pixels/micron. This sampling density is derived from the aliasing error, the resolution loss, and computational limitations. The mathematical and optical methods and equipment used to obtain these results are described in detail.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Harms, H M Aus. 1984. Estimation of sampling errors in a high-resolution TV microscope image-processing system.. https://doi.org/10.1002/cyto.990050303

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evolution of echocardiography.

The evolution of echocardiography has been interesting and dramatic. The technology has grown and has become an integral part of the practice of cardiology. As with all technology, there are advantages and disadvantages. The principal disadvantage is the fact that education and training are imperative to provide high-quality examinations and proper interpretations. In addition, many of the diagnoses are still qualitative and subjective. The principal advantage is the amazing versatility of this technology. The wealth of information that can be provided both noninvasively with a transthoracic examination and invasively with either transesophageal or intravascular ultrasound is tremendous. The anatomic and physiological data provided frequently give definitive diagnoses. If performed properly and for the right reason, this test should be very cost effective and should be a major asset in the coming era of medical cost containment. There are many technological advances that should enhance this information. With technology such as digital recordings, it is hoped that the clinicians will have better access to these data and will be more comfortable in interacting with this important diagnostic tool.

Analog-Digital Conversion

3D computer data capture and imaging applied to the face and jaws.

There have been few attempts in the past at 3D computer modelling of facial deformity because of the difficulties with generating accurate three-dimensional data and subsequent image regeneration and manipulation. We report the application of computer aided engineering techniques to the study of jaw deformity. The construction of a 3D image of the mandible using a Ferranti co-ordinate measuring machine for data capture and the 'DUCT5' surface modelling programme for image regeneration is described. The potential application of this work will be discussed.

Analog-Digital Conversion