PubMed · 6391279
Lung water increases with fluid administration during CPPV after pulmonary microembolization.
Abstract
Hypoxemia created by pulmonary microemboli is improved by continuous positive-pressure ventilation (CPPV) but at a cost of reducing cardiac output (Q). In this high pulmonary vascular resistance (PVR), pulmonary edema setting, the authors attempted to increase the Q, which had been reduced by CPPV, with an infusion of dextran. In 14 dogs, 0.125 g/kg of starch microemboli (63-74 microns in diameter) were infused. CPPV at 15 cm H2O then was applied and PaO2 increased from 53 +/- 4 to 69 +/- 3 mmHg, but Q decreased from 2.9 +/- 0.2 to 1.7 +/- 0.2 1/min. Seven of these dogs (control group) were monitored for 3 h. In the remaining seven dogs (volume group), dextran 40 was infused until Q returned to pre-CPPV values, and monitoring was continued for 3 h. With return of Q to pre-CPPV levels, indices of tissue oxygenation (O2 transport, PVO2, O2 consumption and metabolic acidosis) were significantly improved. However lung water was increased significantly by the volume infusion, so that at 3 h lung water in the volume group was double the value in the control group. The authors conclude that volume infusion in the face of a high PVR may correct the reduced Q of CPPV and improve tissue oxygenation, but it also may increase pulmonary edema.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
W H Noble, J C Kay. 1984. Lung water increases with fluid administration during CPPV after pulmonary microembolization.. https://doi.org/10.1097/00000542-198412000-00012
Cite the original work for its findings. Save a collection to share your selection of sources.