[Methods for testing surface disinfection procedures under current conventional conditions].

Abstract

A method of testing surface disinfection procedures is described with which the same conditions are maintained as those encountered in practice. The disinfectant is applied to surfaces in a conventional manner at a natural scale. A standardised wet-mopping procedure (two-bucket method) applied to floors of glazed clinker serves as a reference. The test method is quantitative. For comparison the same procedure using water of standardised hardness is used. The test parameters are the reduction of the colony count (CC) both on the surface treated and in the used washing water following certain periods of exposure to the disinfectant. For the suitability test of disinfectants the surface is contaminated with reference strains, Kl. pneumoniae ATCC 27736 and Staph. aureus Wood 46. In some special cases wild strains were used for contamination. When testing surface disinfection under user conditions, the flora settling on the surface used is investigated. The bacterial collector after Thran is employed for the extraction of the germs from the surface. Wet mopping with water of standardised hardness has already reduced the count on the floor of Kl. pneumoniae by 2.8 log on average and the count of Staph. aureus by 2.2 log. By the use of the three types of disinfectants tested the count was additionally reduced by 0.45 to 0.72 log for Kl. pneumoniae and by 1.2 to 2.2 log for Staph. aureus. Even after disinfection a spread of germs can be observed; however, it is slight and corresponds to the spread found after the use of water. After mopping with 17 degrees dH water, practically the total germ count applied is found in the cleaning water. After application of the disinfectant the germ counts for Kl. pneumoniae are reduced by 1.8 to 3.7 log and by 3.1 to 3.7 log for Staph. aureus, depending on the type of disinfectant after an exposition of 5 min in the washing water. With respect to Kl. pneumoniae, reduction of the count continues to amount to 2.7 to 3.8 log after 30 min, so that merely 20 to 30 CFU/100 ml washing water remain. The concentration of the disinfectant mainly influences the reduction of germs in the washing water. Thus the analysis of the washing water constitutes an important parameter for the evaluation of a surface disinfectant. The testing procedure proposed is very flexible as it can be readily adapted to the various disinfection problems and evaluation criteria.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Andenmatten, H Reber. 1984. [Methods for testing surface disinfection procedures under current conventional conditions].. https://pubmed.ncbi.nlm.nih.gov/6395572/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sodium hypochlorite: history, properties, electrochemical production.

This paper analyses the evolution of hypochlorite as strong disinfectant. The electrochemical production of hypochloric acid or sodium hypochlorite represents the best method to obtain a pure product. To have a good production (as quality and quantity), it is necessary to optimize the electrochemical process with the optimal of electrocatalytic electrodes (cathode and anode) the gap between electrodes, the temperature of electrochemical cell. It is very important for the product stability during a long period, avoid the presence of heavy metal ions and particulate as impurity-like carbon micro-powders in suspension. It is necessary a rigorous control of the pH of final product to have the optimal disinfection power of hypochlorite solution. The most stable sodium hypochlorite solutions are those that show the following characteristics: (1) low concentration of hypochlorite; (2) pH -> 11.5 and <13; (3) absence of graphite particulate and metallic ions; (4) storage at controlled temperature <30 degrees C. Packing in containers impermeable to light.

Disinfectants↗

Disinfection of dialysis monitors.

In recent years the concept of biocompatibility is not limited to the dialytic membranes, but has been substituted by a more general viewpoint where all the parameters of the dialytic treatment are taken into consideration: the interaction of blood-surfaces (the dialyzer in all its components and the hematic lines), the sterilization of all materials, the quality of the solutions utilized for dialysis and reinfusion. Numerous studies have shown that the inflammatory response in dialysis is the cause of many of the side effects of dialytic treatment itself both acute and chronic. Hypoxemia, 'first use' syndrome, hypotension, allergic-anaphylactic reactions (short-term side effects); microinflammation, malnutrition, accelerated arteriosclerosis, anemia, beta2 microglobulin amyloidosis, immunodeficiency, bone mass loss (long-term side effects), have all been reported. In this review, we will focus on the fluids utilized for hemodialysis (HD) and hemodiafiltration (HDF); we will describe the process of disinfection of the machines which produce the dialytic solutions.

Disinfectants↗

Disinfection of lines and transfer sets in peritoneal dialysis.

Peritoneal dialysis (PD) exchanges require sterile equipment, supplies, and technique. Sterility may be maintained with single use. However, when equipment such as lines and transfer sets are used repeatedly, disinfection techniques become a critical aspect in preventing infectious complications. Techniques available for disinfection of lines and transfer sets in PD will be reviewed.

Disinfectants↗