PubMed Health⌕ Search

PubMed · 6460138

A microcomputer-based drop counter.

Abstract

A microcomputer-based drop counter is described that allows the accurate measurement of fluid flows up to about 5 ml/min. Detailed construction information is included. Unlike most previously described drop counters, it displays flow directly in ml/min and calculates a confidence limit for the measurement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Lee, J Downey. 1981. A microcomputer-based drop counter.. https://doi.org/10.1016/0160-5402(81)90114-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The impact of diabetes on left ventricular filling pattern in normotensive and hypertensive adults: the Strong Heart Study.

OBJECTIVES: We sought to determine the effect of diabetes mellitus (DM) on left ventricular (LV) filling pattern in normotensive (NT) and hypertensive (HTN) individuals. BACKGROUND: Diastolic abnormalities have been extensively described in HTN but are less well characterized in DM, which frequently coexists with HTN. METHODS: We analyzed the transmitral inflow velocity profile at the mitral annulus in four groups from the Strong Heart Study: NT-non-DM (n = 730), HTN-non-DM (n = 394), NT-DM (n = 616) and HTN-DM (n = 671). The DM subjects were further divided into those with normal filling pattern (n = 107) and those with abnormal relaxation (AbnREL) (n = 447). RESULTS: The peak E velocity was lowest in HTN-DM, intermediate in NT-DM and HT-non-DM and highest in the NT-non-DM group (p < 0.001), with a reverse trend seen for peak A velocity (p < 0.001). In multivariate analysis, E/A ratio was lowest in HTN-DM and highest in NT-non-DM, with no difference between NT-DM and HTN-non DM (p < 0.001). Likewise, mean atrial filling fraction and deceleration time were highest in HTN-DM, followed by HTN-non-DM or NT-DM and lowest in NT-non-DM (both p < 0.05). Among DM subjects, those with AbnREL had higher fasting glucose (p = 0.03) and hemoglobin A1C (p = 0.04). CONCLUSIONS: Diabetes mellitus, especially with worse glycemic control, is independently associated with abnormal LV relaxation. The severity of abnormal LV relaxation is similar to the well-known impaired relaxation associated with HTN. The combination of DM and HTN has more severe abnormal LV relaxation than groups with either condition alone. In addition, AbnREL in DM is associated with worse glycemic control.

Blood Flow Velocity↗

Accurate noninvasive estimation of pulmonary vascular resistance by Doppler echocardiography in patients with chronic failure heart failure.

OBJECTIVES: This study was undertaken to explore further the relationship between Doppler-derived parameters of pulmonary flow and pulmonary vascular resistance (PVR) and to determine whether PVR could be accurately estimated noninvasively from Doppler flow velocity measurements in patients with chronic heart failure. BACKGROUND: The assessment of PVR is of great importance in the management of patients with heart failure. However, because of the inconclusive and conflicting data available, Doppler estimation of PVR is still considered unreliable. METHODS: Simultaneous Doppler echocardiographic examination and right heart catheterization were performed in 63 consecutive sinus rhythm heart failure patients with severe left ventricular systolic dysfunction. Hemodynamic PVR was calculated with the standard formula. The following Doppler variables on pulmonary flow and tricuspid regurgitation velocity curve were correlated with PVR: maximal systolic flow velocity, pre-ejection period (PEP), acceleration time (AcT), ejection time, total systolic time (TT), velocity time integral, and right atrium-ventricular gradient. RESULTS: At univariate analysis, all variables except maximal systolic flow velocity and velocity time integral showed a significant, although weak, correlation with PVR. The best correlation found was between AcT and PVR (r = -0.68). By regression analysis, only PEP, AcT and TT entered into the final equation, with a cumulative r = 0.87. When the function (PEP/AcT)/TT was correlated with PVR, the correlation coefficient further improved to 0.96. Of note, this function prospectively predicted PVR (r = 0.94) after effective unloading manipulations. CONCLUSIONS: The analysis of Doppler-derived pulmonary systolic flow is a reliable and accurate tool for estimating and monitoring PVR in patients with chronic heart failure due to left ventricular systolic dysfunction.

Blood Flow Velocity↗

[IGFBP-1 and its protective role in the pathogenesis of microangiopathy in type 1 diabetes mellitus].

BACKGROUND: The role of IGF-I/IGFBP's system in the pathogenesis of diabetic vascular complications is widely discussed in the literature. We studied the influence of this system on microvasculature in patients with type 1 diabetes with respect to the effect of IGFBP-1. METHODS AND RESULTS: 17 patients with type 1 diabetes were included in the study. We examined IGF-I, IGFBP-1 and IGFBP-3 serum levels, parameters of compensation of diabetes and basic values of lipid metabolism. The function of microvasculature was examined using the laser-Doppler system Periflux. We didn't found any relation between the total IGF-I serum levels, parameters of lipid metabolism or level of diabetes compensation and the degree of impairment of the function of microcirculation. IGFBP-1 serum levels positively correlated with the peak perfusion in thermal hyperaemia (r = 0.39; p < 0.03). IGFBP-3 serum levels did not affect the function of microcirculation. CONCLUSION: We can conclude that the activity of IGF-I/IGFBP's system belongs to factors contributing to the development of diabetic microangiopathy in type 1 diabetes. IGFBP-1 as the modulator of IGF-I activity plays probably protective role against the progression of microangiopathy. These results correspond with observations of some other authors.

Blood Flow Velocity↗