PubMed HealthSearch

PubMed · 6486548

Method for rapid fluid replacement questioned.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K V Iserson, A K Reeter. 1984. Method for rapid fluid replacement questioned.. https://doi.org/10.1016/s0196-0644(84)80097-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air

Intracranial microembolic signals in patients with artificial heart valves: drowning in numbers.

Five years after the first description of Doppler microembolic signals, both their clinical significance and underlying material remain a matter of debate. It appears certain that MES depend on valve type and position, while their relation to other clinical parameters, including neurological complications, is still unclear. A number of clinical and experimental studies are reviewed, most of which argue towards gaseous embolic material.

Embolism, Air

[Lethal portal venous gas after cardiopulmonary arrest].

We report the case of a 51-year-old patient admitted after a transient cardiorespiratory arrest. The abdominal CT scan revealed the presence of hepatic portal venous gas. At laparotomy, a diffuse mesenteric ischaemia was diagnosed. The patient died from multiple organ failure in the subsequent hours. Necrotic bowel is associated with hepatic portal venous gas in 50% of the cases and the current mortality rate is 85%. Gas originates either through intestinal transmucosal passage, either by intraportal bacterial gas production, or through both mechanisms.

Embolism, Air