Diffuse and localized nerve fiber loss in glaucoma.

Abstract

To estimate the usefulness of photographs of the retinal nerve fiber layer in demonstrating glaucomatous neural tissue changes, we examined such photographs of 51 patients with glaucoma, 52 patients with ocular hypertension, and 29 normal individuals. The photographs were assessed in a masked fashion. A semiquantitative damage score was given in subsectors of the arcuate, papillomacular, and nasal nerve fiber bundle areas, separately for localized and diffuse loss of nerve fibers. The coefficients of variation of the reproducibility of retinal nerve fiber layer assessment were 0.22 for diffuse damage and 0.11 for localized damage. We detected abnormal retinal nerve fiber layer changes in 48 of the patients with glaucoma, in 27 of those with ocular hypertension, and in five of the normal control subjects. Generalized reduction of nerve fibers with or without localized defects was more common in patients with glaucoma than in those with ocular hypertension whose abnormal findings were primarily localized defects.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Airaksinen, S M Drance, G R Douglas, D K Mawson, H Nieminen. 1984. Diffuse and localized nerve fiber loss in glaucoma.. https://doi.org/10.1016/0002-9394(84)90242-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗