PubMed Health⌕ Search

PubMed · 6503259

A controllable artificial afterload for isolated heart studies.

Abstract

This paper presents an artificial afterload, based on the Westerhof model, for use in isolated heart preparations. The system has adjustable elements representing peripheral resistance and total arterial compliance, together with a fixed element representing aortic impedance. It is controlled by a computer in a manner which incorporates feed forward and feedback techniques. The system maintains constant 'arterial' pressure in the face of large excursions of the flow through it. It can be programmed to change this pressure in a dynamic fashion. The time taken to recover from large changes in flow and to reset the pressure is at most 3 S. Absolute values of peripheral resistance are easily obtained without any knowledge of the actual flow being required. Tests of the system demonstrate its stability and rapid transient characteristics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Fisher, R E Challis, P Swann. 1984. A controllable artificial afterload for isolated heart studies.. https://doi.org/10.1016/0141-5425(84)90080-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗