PubMed · 6507384
A solid phase antibody screen.
Abstract
An automated solid phase antibody screen (SPAS) in microplates has been developed. Red blood cell (RBC) adherence was used as the end point instead of agglutination. Consequently, positive and negative reactions were readily distinguished by a microplate spectrophotometer. The SPAS performed as well as conventional antiglobulin methods for detecting IgG antibodies in donor sera and had increased sensitivity as determined by serial dilutions of antibodies.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
F V Plapp, L T Sinor, J M Rachel, M L Beck, W M Coenen, W L Bayer. 1984. A solid phase antibody screen.. https://doi.org/10.1093/ajcp%2F82.6.719
Cite the original work for its findings. Save a collection to share your selection of sources.