Abstract

Medical research in general and equipment comparisons in particular suffer from a deficiency and disparity of statistical analysis. We studied four semi-automatic sphygmomanometers in comparison with the Hawksley random zero mercury manometer. The Astropulse 80 showed marked deviation from the standard machine in average blood pressure recorded and greater variation of readings. The Infrasonde M3010, Bosomat II and Infrasonde D4000 were similar to the standard machine. To help comparability in future studies we suggest the following guidelines; blood pressures to be taken under standard conditions, data to be shown as scatterplots, analysis of variance to be performed and regression analysis to be used only to give an approximate overall view. Finally, we urge the manufacturing companies to conduct such studies and include the results in their brochures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Sloan, A Zezulka, P Davies, A Sangal, M Beevers, D G Beevers. 1984. Standardized methods for comparison of sphygmomanometers.. https://doi.org/10.1097/00004872-198410000-00016. https://pubmed.health/record/pubmed%3A6530556/standardized-methods-for-comparison-of-sphygmomanometers

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Central venous pulse pressure analysis using an R-synchronized pressure measurement system.

OBJECTIVE: The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. METHODS: Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. RESULTS: CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. CONCLUSIONS: The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.

Blood Pressure Determination↗

Beyond inpatient and outpatient care: alternative model for hypertension management.

Hypertension is a major contributor to worldwide cardiovascular mortality, however, only one-third of patients with hypertension have their blood pressure treated to guideline recommended levels. To improve hypertension control, there may need to be a fundamental shift in care delivery, one that is population-based and simultaneously addresses patient, provider and system barriers. One potential approach is home-based disease management, based on the triad of home monitoring, team care, and patient self-care. Although there may be challenges to achieving the vision of home-based disease management, there are tremendous potential benefits of such an approach for reducing the global burden of cardiovascular disease.

Blood Pressure Determination↗