A versatile computer-controlled biological stimulus sequencer.

Abstract

A computer-controlled stimulus sequencer has been developed. This device can be controlled by several commonly available, inexpensive 8-bit microcomputers in which the address, data, and control lines are externally accessible. Although the Apple implementation has been described, a similar interface has also been devised for the Radio Shack Color Computer. The hardware relies on the Rockwell Versatile Interface Adapter (VIA) chip (which has two 16-bit timers capable of functioning as frequency dividers, event counters, or one-shots) and a 12-bit digital-to-analog converter (DAC) chip. This hardware combination, along with software written in Basic and machine language (stored in an EPROM for turn-key operation), allows creation of a large number of unique trains that can be chained together in any sequence. This is aided by storing the train characteristics economically in the computer memory and chaining different train parameters in a link-list. Several train parameters can be incremented or decremented manually by a pair of keys. The amplitude of the train can be changed manually or under program control. Once created, the trains can be edited on the run or deleted from the sequence. The device also generates a trigger pulse that can be referenced to any pulse in a train and can be used to pretrigger an oscilloscope. The software has provision for detecting an external signal, and this information can be used to modify train parameters. The interface is interrupt driven and therefore does not require continuous use of the Basic interpreter.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Boyechko, D Bose. 1984. A versatile computer-controlled biological stimulus sequencer.. https://doi.org/10.1016/0160-5402(84)90005-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The promise of computerized feedback systems for diabetes care.

Feedback control is an important mechanism for reaching a targeted goal. Biologic examples range from achieving the appropriate blood pressure level to glycemia control. Computer-based feedback control systems have many potential applications in medicine. Closed-loop systems directly sense the state of the patient and then deliver an intervention without human action. Closed-loop systems have been used to control postoperative fluid infusion, reduce malignant hypertension to a reasonable range through nitroprusside infusions, and control continuous insulin infusions-in effect, an artificial pancreas. Sensory problems have limited the direct application of closed-loop systems to date; most current medical uses of computer-based feedback control are open loop, where a human is interposed between the suggested intervention and the delivered treatment. Because many variables important to the management of diabetes are objective, many opportunities exist for open-loop control in diabetes management. Open-loop systems have already been used to suggest insulin dosage adjustments and treatment for hypercholesterolemia and to remind physicians of various mellitus. However, existing applications have only scratched the surface. Many more facets of diabetes management could be standardized and assisted by open-loop control systems if the management rules could be more exactly specified, a task requiring substantial time commitments by diabetologists. Efforts to translate existing knowledge bases into precise guidelines will be helpful, but new primary studies and decision analyses are needed to define the optimal use of some interventions.

Computers

Manual versus computer-automated semen analyses. Part I. Comparison of counting chambers.

OBJECTIVE: To determine the accuracy and precision of counting chambers analyzed manually and with a computer-automated semen analyzer (CASA; Hamilton-Thorne Research, Beverly, MA). DESIGN: Prospective study using comparative measurements of sperm concentration, motility and concentration of latex beads with three types of counting chambers: hemacytometers, 12 and 20 MicroCell (Conception Technologies, Inc., La Jolla, CA) Chambers, and Makler (Sefi-Medical Instruments, Haifa, Israel) Chambers. SETTING: A hospital-based Andrology laboratory. PATIENTS: Male partners of couples undergoing infertility evaluation. MAIN OUTCOME MEASURES: Experiment I: measurements of sperm concentration were evaluated within hemacytometers; Experiment II: measurements of sperm concentration in the 35 to 50 x 10(6)/mL range and sperm motility were determined using a known concentration of beads. RESULTS: Experiment I: differences were demonstrated within two of eight hemacytometers (side 1 versus side 2): however, no significant effect of hemacytometer on variation in sperm concentration measurements was observed. Experiment II: CASA-analyzed 20 MicroCell Chambers demonstrated the best precision for sperm concentration (intraclass correlation coefficient = 0.93) and motility (intraclass correlation coefficient = 0.88). Experiment III: 20 MicroCell Chambers most accurately determined known bead concentration (35 +/- 5 x 10(6)/mL) whether analyzed on CASA (34.9 x 10(6)/mL) or manually (35.2 x 10(6)/mL). CONCLUSIONS: 20 MicroCell Chambers proved to be accurate and precise for determining concentration and motility of semen specimens whether analyzed manually or with CASA.

Computers