PubMed HealthSearch

PubMed · 6559823

Data processing for radioimmunoassay standard curve using microcomputer: a new BASIC program for weighted logit-log transformation.

Abstract

A new BASIC program of the weighted linear, quadratic and cubic logit-log regression methods for data processing of radioimmunoassay standard curve was developed using a microcomputer. Using this program, three regression analyses are calculated and the table for root mean square of residuals in each regression are shown for the selection of the regression method. The data of three radioimmunoassays of human pancreatic enzymes and pancreatic secretory trypsin inhibitor were examined by this program and compared with those processed by the four parameter logistic method. The weighted cubic logit-log regression showed better fit in radioimmunoassays of human pancreatic enzymes with larger molecular weights. The present program is useful and practicable for its simplicity and accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Murata, M Ogawa, K Matsuda, T Kitahara, S Nishibe, E Kurokawa, G Kosaki. 1983. Data processing for radioimmunoassay standard curve using microcomputer: a new BASIC program for weighted logit-log transformation.. https://doi.org/10.1080/15321818308057018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The promise of computerized feedback systems for diabetes care.

Feedback control is an important mechanism for reaching a targeted goal. Biologic examples range from achieving the appropriate blood pressure level to glycemia control. Computer-based feedback control systems have many potential applications in medicine. Closed-loop systems directly sense the state of the patient and then deliver an intervention without human action. Closed-loop systems have been used to control postoperative fluid infusion, reduce malignant hypertension to a reasonable range through nitroprusside infusions, and control continuous insulin infusions-in effect, an artificial pancreas. Sensory problems have limited the direct application of closed-loop systems to date; most current medical uses of computer-based feedback control are open loop, where a human is interposed between the suggested intervention and the delivered treatment. Because many variables important to the management of diabetes are objective, many opportunities exist for open-loop control in diabetes management. Open-loop systems have already been used to suggest insulin dosage adjustments and treatment for hypercholesterolemia and to remind physicians of various mellitus. However, existing applications have only scratched the surface. Many more facets of diabetes management could be standardized and assisted by open-loop control systems if the management rules could be more exactly specified, a task requiring substantial time commitments by diabetologists. Efforts to translate existing knowledge bases into precise guidelines will be helpful, but new primary studies and decision analyses are needed to define the optimal use of some interventions.

Computers