Nested control procedures for internal analytical quality control. Theoretical design and practical evaluation.

Abstract

A quality control system has been developed and evaluated for three Greiner automatic analyzers. The control system was built in a hierarchical way with different statistical rules for different stages of the analytical process. Computer simulation techniques were found to be very helpful in grasping the quantitative aspects of various design features. In the practical evaluation of the control system the calculated rates of false rejections were of the same order as the theoretical value of 0.01 in most cases, and the estimated frequencies of analytical disturbances varied between 0 and 0.25.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Aronsson, T Groth. 1984. Nested control procedures for internal analytical quality control. Theoretical design and practical evaluation.. https://pubmed.ncbi.nlm.nih.gov/6599530/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer CellDyn 3500 and the urine flow cytometer UF-100.

BACKGROUND: The counting of leukocytes and erythrocytes in cerebrospinal fluid (CSF) is still performed microscopically, e.g., using a chamber in most laboratories. This requires sufficient practical experience, is time-consuming, and may constitute a problem in emergency diagnostics. Specific automated systems for CSF cell counting are not available at present. METHODS: We tested the hematology analyzer CellDyn 3500 (CD) and the urine flow cytometer UF-100 (UF), which are not designed for CSF analysis. We studied >104 samples with both analyzers, and the counts obtained were compared with the reference method (Fuchs-Rosenthal chamber). RESULTS: Good linearity in the medically relevant range of 15 x 10(6) to 1000 x 10(6) leukocytes/L and a high degree of within-run accuracy were seen for both analyzers. Cell counting on the UF was excellent, especially when low cell counts were encountered (CV, 4. 9% compared with 28% observed for the CD). Method comparison showed that identical results could be detected for a majority of the count pairs. For a few samples, there was a discrepancy between the results from the analyzers and the counting chamber. In most cases, these were CSF samples containing a high proportion of lymphocytes. For these samples, the CD result led to a false-positive high leukocyte count, and on the UF these cells were not allocated to the leukocyte population, thus leading to false-negative counts. CONCLUSIONS: Both analyzers should not be used for CSF cell counting in all cases at present. However, once the technical and software problems have been solved, routine use of the two analyzers for CSF analysis should be seriously contemplated.

Autoanalysis

Rapid method for relative gene expression determination in human tissues using automated capillary gel electrophoresis and multicolor detection.

The aim of this study was to evaluate a direct and automated post-polymerase chain reaction (PCR) detection system to simultaneously determine the relative gene expression levels of nine cancer-related human genes. Total RNA was prepared from flash-frozen biopsies derived from human colorectal tumors or normal mucosa and reverse-transcribed to cDNA which was PCR-amplified using primer pairs corresponding to the studied genes. In each reaction, the forward primer was labeled with a fluorescent dye. The PCR products were pooled and an internal size standard with a uniquely colored fluorescent dye was added. The samples were then subjected to automated capillary gel electrophoresis. Fragment analysis software was used to calculate the relative gene expression using beta-actin as the reference gene. We found that automated capillary gel electrophoresis with multicolor detection is a rapid, accurate and highly reproducible method for separation and quantification of PCR-amplified cDNA.

Autoanalysis

Tandem mass spectrometry linked fraction collection for the isolation of drug metabolites from biological matrices.

An automated mass spectrometric linked fraction collection system is described which enables on-line examination of isolated components based on molecular-ion and product-ion information. This system has been used successfully to specifically isolate drug-related material from complex biological fluids to aid structural identification. Metabolites have been isolated with sufficient purity to allow unequivocal characterisation by 1H nuclear magnetic resonance spectroscopy. This system has the advantage that isolation of the components of interest is not triggered by a simple contact closure. Therefore fraction collection is not biased by limitations in either the detector (e.g. insufficient sensitivity) or the analyst (e.g. programmed collection of predicted metabolites only). Furthermore, all isolated components are readily available post fractionation for additional screening.

Autoanalysis