[Close-range retinoscopy using integrated optic range finding].

Abstract

A new type of retinoscope is described which permits all the theoretical advantages of close-range retinoscopy to be exploited in practice thanks to an integrated rangefinder which employs the coincident-image principle.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Kulnig. 1983. [Close-range retinoscopy using integrated optic range finding].. https://doi.org/10.1055/s-2008-1054998

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance evaluation of a prototype high resolution digital radiographic/near real-time fluoroscopic computerized tomographic system for radiotherapy simulation.

PURPOSE: A new prototype digital radiographic/near real-time fluoroscopic and computerized tomographic (CT) imaging system has been developed and its performance is evaluated for future implementation in a radiotherapy simulator. METHODS AND MATERIALS: The new imaging modality uses a slow scan cooled charge-coupled device (CCD) camera with 2 k x 2 k x 12 bit image resolution. X-ray images formed by a Gd2O2S:Tb flat screen are directly viewed by the CCD camera via a 45 degrees angled mirror and a high speed objective lens. For CT image reconstruction, digital data from a slit image on the CCD array obtained from time-controlled x-ray scans around the object are transferred to a second tomographic computer for processing and display. RESULTS: In the digital radiographic mode, and for a 43.2 x 43.2 cm field size at the phosphor plane, the spatial resolution of the system is 2.3 +/- 0.1 lp/mm (1 sigma) as measured at the 4% level of the modulation transfer function (MTF), whereas the contrast resolution has a value of 0.5%. In the fluoroscopic mode, the system may be operated at a maximum rate of eight frames/s at a relatively lower spatial and contrast resolution. For CT scans, although the potential intrinsic spatial resolution at the isocenter is 0.35 mm, display-limited spatial resolutions of 1.2 and 1.6 mm were obtained for 30 and 40 cm reconstruction circle diameters, respectively. A contrast resolution of 1% at 0.015 Gy entrance dose was achieved, and CT reconstruction circles of up to 51 cm were attainable. CONCLUSION: The new CCD-based imaging system is capable of delivering high-quality digital radiographic and CT images for radiotherapy simulation, whereas the near real-time fluoroscopic mode yields acceptable flicker-free lower quality images at object speeds typical of simulation motions.

Fluoroscopy

Are hard-copy prints from peroperative fluoroscopy images useful as documentation?

We have examined the applicability of peroperative image documentation, in promoting early mobilization after osteosynthesis and saving the standard X-ray examination. One hundred and twenty-three patients with proximal femoral fractures were included in the investigation. Hard-copy reprints were recorded from peroperative fluoroscopy images by Fuji Film Thermal Imaging System FTI 200. These reprints were compared with the standard X-rays to assess the quality of the osteosynthesis and possible restriction in mobilization. The specificity of finding an unstable osteosynthesis was 0.40, whereas the sensitivity of finding a stable osteosynthesis was 0.96. In all, four unstable osteosyntheses were overlooked on the hard copy reprints. The specificity of finding patients in need of restricted mobilization was 0.44 and the sensitivity of finding patients allowed free mobilization was 0.93. Eight patients needing restricted mobilization were overlooked on the reprints. Hard-copy images do not safely reveal unstable osteosynthesis and cannot replace the standard X-rays taken postoperatively.

Fluoroscopy