The anesthesia machine: current design and alternatives.

Abstract

The anesthesia machine is a major component in an integrated anesthesia care system. It can be considered in terms of the functional subsystems responsible for gas proportioning, anesthetic vapor delivery, patient ventilation, and waste gas scavenging. Alternative technologies for these functional units should be examined in light of the disadvantages inherent in present machines. Safety features, often added on an ad hoc basis, should instead be designed into the machine itself. The anesthesia delivery system should include feedback about the patient status and device performance, as well as provide for the delivery of anesthetic and pharmacologic agents. Improvements in performance and provisions for automation of some functions should be considered as future design criteria.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C K Waterson. The anesthesia machine: current design and alternatives.. https://pubmed.ncbi.nlm.nih.gov/6669097/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗