Decrease in airway pressure during high-frequency jet ventilation in infants with respiratory distress syndrome.

Abstract

Using a crossover study design, we compared a system of high-frequency jet ventilation with appropriate humidification to pressure-limited conventional ventilation in 12 preterm infants with a birth weight of 1.9 +/- 0.6 kg and gestational age of 32 +/- 2 weeks who had severe respiratory distress syndrome. After a control period of conventional ventilation, high-frequency jet ventilation was administered for 1 to 3 hours at a constant rate (250/min) and inspiratory to expiratory time (1:3 or 1:4) in the same fraction of inspired oxygen as during conventional ventilation. Average peak inspiratory pressure decreased from 29 +/- 3 cm H2O during conventional ventilation to 20 +/- 4 cm H2O during high-frequency jet ventilation (P less than 0.001), whereas positive end expiratory pressure was unchanged, resulting in a reduction in mean airway pressure from 14 +/- 3 to 10 +/- 2 cm H2O (P less than 0.001). There was a simultaneous decrease in PaCO2 (39 +/- 4 to 34 +/- 4 mm Hg, P less than 0.01), but PaO2 did not change. These data indicate that short-term high-frequency jet ventilation maintains gas exchange in infants with respiratory distress syndrome despite a lower PIP and Paw, and results in smaller airway pressure swings than during conventional ventilation. Thus, high-frequency jet ventilation may offer hope for reducing barotrauma in this population.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W A Carlo, R L Chatburn, R J Martin, M D Lough, C R Shivpuri, J V Anderson, A A Fanaroff. 1984. Decrease in airway pressure during high-frequency jet ventilation in infants with respiratory distress syndrome.. https://doi.org/10.1016/s0022-3476(84)80604-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Umbilical cord blood gas analysis; a comparison of two simple methods of sample storage.

Umbilical cord vessel acid-base analysis is increasingly employed as an end-point in the study of ante-partum and intra-partum care. Delay in processing the sample can results in erroneous values as a result of gaseous diffusion and continuing metabolism. The effect of delay was investigated for samples stored in heparinized syringes at room temperature and simultaneously stored samples in double clamped cord segments. Small, but statistically significant changes were seen for pH, base deficit and PCO2 over 30 min. Storage in the syringe results in the most reliable values for pH and base deficit, whereas the cord segments showed no changes in PO2 and PCO2.

Blood Gas Analysis

Defusing status epilepticus.

The risk of brain neuron death supersedes that of physical harm due to muscle spasms. In fact, immediate induction of neuromuscular paralysis impedes monitoring of anticonvulsant therapy, which can be empiric but should follow a predetermined, sequential protocol so that seizures can be terminated quickly.

Blood Gas Analysis