PubMed · 671249
Fluorometric assay for urinary indapamide.
Abstract
A sensitive fluorescence method for the determination of indapamide was developed. Reaction of indapamide with sodium hydroxide at 100 degrees yielded a fluorescent product, and addition of formaldehyde to the fluorescent product increased its fluorescence intensity by a factor of three. The assay is sensitive to levels of indapamide of 0.025 microgram/ml in an aqueous solution, and a linear response between 0.025 and 2.0 microgram/ml was observed. The procedure was adapted to the analysis of intact indapamide in urine. Concentrations of indapamide of 0.05 microgram/ml can be detected in dogs given 20 mg of the drug.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
P E Grebow, J A Treitman, A K Yeung. 1978. Fluorometric assay for urinary indapamide.. https://doi.org/10.1002/jps.2600670824
Cite the original work for its findings. Save a collection to share your selection of sources.