PubMed HealthSearch

PubMed · 6713060

Microprocessor-controlled flow injection analyzer for biochemical applications.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Ho. 1984. Microprocessor-controlled flow injection analyzer for biochemical applications.. https://pubmed.ncbi.nlm.nih.gov/6713060/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Polymer- versus silica-based separation media: elimination of nonspecific interactions in the chiral recognition process through functional polymer design.

A novel chiral stationary phase that contains a new chiral selector based on L-valine-3,5-dimethylanilide attached to monodisperse poly(glycidyl methacrylate-co-ethylene dimethacrylate) beads has been prepared. The polymeric separation medium provides greatly enhanced enantioselectivities and reduced retention times when compared to the analogous silica-based chiral stationary phase in the separation of the enantiomers of 3,5-dinitrobenzamido derivatives of alpha-amino acids under normal-phase HPLC conditions. Separation factors (alpha) of up to 7 were achieved with the polymeric separation medium, which is also useful for the separation of large samples under overload conditions.

Chemistry Techniques, Analytical

Separation by blue native and colorless native polyacrylamide gel electrophoresis of the oxidative phosphorylation complexes of yeast mitochondria solubilized by different detergents: specific staining of the different complexes.

Blue native polyacrylamide gel electrophoresis (BN-PAGE) or colorless native polyacrylamide gel electrophoresis (CN-PAGE) allowed separation of the oxidative phosphorylation complexes of yeast mitochondria. These complexes were characterized by specific staining related to their enzymatic activity. Solubilization of mitochondria by different nonionic detergents such as Triton X-100, dodecyl maltoside, Nonidet P-40, Lubrol, octyl glucoside, or Hecameg led to the separation of F1-FO ATPase complexes exhibiting distinct apparent molecular masses related to different contaminating proteins and lipids. All these different forms were active in ATP hydrolysis as revealed directly on the gel. Analysis of the subunit composition of these complexes was carried out by a two-dimensional Tricine-SDS-PAGE and showed that the purest F1-FO ATPase complex was obtained with Lubrol, whereas with Hecameg and octyl glucoside, only the F1 part of ATPase was solubilized.

Chemistry Techniques, Analytical

Biochemical method for chlorine dioxide determination.

Chlorine dioxide is a disinfectant used worldwide. In this article, a new enzymatic method for the determination of chlorine dioxide has been developed. This rapid spectophotometric assay is able to detect from 0.2 to 4 mg/liter of chlorine dioxide. The method is based on the capacity of horseradish peroxidase to decolorize reactive yellow 17 in the presence of chlorine dioxide. The effects of several compounds on the assay have been determined. Except sodium hypochlorite, no interference was detected with 18 compounds including chlorides, sulfates, carbohydrates, amino acids, proteins, and organics. The biochemical method is faster and easier than the previous volumetric, amperometric, and colorimetric methods which are laborious and time-consuming.

Chemistry Techniques, Analytical