A method for socket duplication using Silcoset R 105.

Abstract

A technique for duplicating an existing comfortable socket has been in use for two years. The method, using Silcoset R 105, provides the prosthetist with a re-usable positive mould thus enabling the manufacture of two prostheses of comparable fit.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N J Young. 1984. A method for socket duplication using Silcoset R 105.. https://doi.org/10.3109/03093648409145346

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Real time microcontroller implementation of an adaptive myoelectric filter.

This paper describes a real time digital adaptive filter for processing myoelectric signals. The filter time constant is automatically selected by the adaptation algorithm, giving a significant improvement over linear filters for estimating the muscle force and controlling a prosthetic device. Interference from mains sources often produces problems for myoelectric processing, and so 50 Hz and all harmonic frequencies are reduced by an averaging filter and differential process. This makes practical electrode placement and contact less critical and time consuming. An economic real time implementation is essential for a prosthetic controller, and this is achieved using an Intel 80C196KC microcontroller.

Artificial Limbs

From wooden limbs to biomaterial organs: the ethics of organ replacement and artificial organs.

This paper discussed issues of ethical assessment and moral concern associated with organ replacement and physical enhancement: research, allocation, organ donation, artificial organs, xenografts, biomaterials, and neuromaterials. While emphasizing the medical and moral benefits over associated risks, it calls for a better integration of moral assessment into technology assessment and for the establishment of a cross-cultural and interdisciplinary International Ethics Committee for Organ Replacement Therapy.

Artificial Limbs

Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.

During the next decade CAD/CAM technique will probably become routine in prosthetics and orthotics, not only as a complement to manual techniques, but also introducing new possibilities. However, even complex and sophisticated techniques have errors of measurement that must be considered. Such errors are of two principal kinds: systematic errors and random errors. In this study we have evaluated the Swedish CAPOD system with respect to volumetric determinations. We used two types of reference objects for volume determinations: cylinders and amputation residual limb models. Three different sizes were examined of each type of object. Volume measurements with CAPOD were compared with volumes obtained by water immersion or mathematical calculation (cylinders only). We found a constant, linear systematic error of +2.5%. Such an error can easily be corrected for. The random error, represented by the coefficient of variation, was 0.5%, which means that there is a theoretical possibility to detect volume changes exceeding 1%. We consider the precision sufficient for clinical practice in prosthetics and orthotics. Biological variations due to soft tissue deformation must be added on top of these errors. Such deformations were not evaluated in this study.

Artificial Limbs