PubMed · 6810078

Compensating filters for high energy x rays.

Abstract

In order to produce individualized compensating filters for use with high energy x rays, a study was undertaken to study lead as a filter material using 10-MV x rays. As was expected, it was found that lead filters could be constructed for 10-MV x rays by extending concepts developed for cobalt-60 gamma rays. A quantity called the "effective attenuation coefficient" (mueff) was determined for a range of field sizes, initial depths in water, and lead thicknesses and for 100-cm SSD and 150-cm SSD treatment techniques. Slight variations of mueff with field area and filter thickness were discernable. However, a single value of this parameter could reproduce the original depth of missing tissue data with an rms error of 2 mm. Tests were then performed on filters whose shapes were calculated using the effective attenuation coefficient. Compensating filters restored the flatness of 10-MV x-ray beams to better than 5%, which was better than comparable filters using cobalt-60 gamma rays. The technique is presented as generally reliable for constructing compensating filters for use with high energy linear accelerators.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A L Boyer. Compensating filters for high energy x rays.. https://doi.org/10.1118/1.595225

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On a simple method for routine check of the constancy of radiation quality of bremsstrahlung emitted by therapeutic particle accelerators.

The constancy of radiation quality of therapeutically employed particle accelerators has to be checked at weekly intervals. Any change in radiation quality may have considerable therapeutic effects owing to its influence on dose distribution. It can be recommended to make measurements instead of, or in addition to, the axial reference-point measurement at 5 and 15 cm depth in the phantom, at 5 cm depth in the beam axis and at a reference-point about 1 cm within the geometric edge of the field, for checking the constancy of the radiation quality of bremsstrahlung. Only then, if routine checks carried out for the axial and the lateral reference-point dose ratios do not show any deviations greater than e.g. +/- 2%, radiation quality is deemed to have remained sufficiently constant for radiotherapeutical applications.

Radiotherapy, High-Energy↗

Accessory beam flattening filter for the varian clinac-4 linear accelerator.

An accessory beam flattening filter (brass disk with critical angles) attaches to the shadow tray of the clinac-4 linear accelerator, intercepts the x-ray beam, and eliminates higher dose areas at the edges of large fields near the skin surface. This improves the x-ray beam dose distribution within the patient and results in a reduction of dose to normal tissues near the surface.

Radiotherapy, High-Energy↗

Extended field treatment flatness filter for 4 MV linear accelerators.

An auxiliary flatness filter for large field treatment on 4 MV linear accelerator provides an isodose distribution which does not vary more than 6% over the central 80% of the axis of a 32 x 32-cm field at 80 cm in air, and at a 2.5, 6, and 12-cm depth in water. This lead disc filter does not affect the central axis depth dose values, and results in only a 16% reduction in dose rate on the central field axis.

Radiotherapy, High-Energy↗