Abstract

A quality control program which related quality control data to maintenance procedures has been developed. Whole blood tonometered at three levels of pCO2 and pO2 is used as the quality control material. A key feature of the program is that control values are independent of barometric pressure. The recording format consolidates results at all levels for each constituent, and permits direct comparison with maintenance procedures or electrode changes. The tonometry system consists of a precision gas mixer, Corning Model 192, and a two-channel syringe tonometer, Corning Model 184. This system provides several advantages for quality control, including: (1) use of Levy-Jenning charts with constant "mean values" for tonometered blood; (2) evaluation of electrode linearity over a wide range of partial pressures; and (3) multiple values for each parameter tested. Recovery of theoretical values over a broad range of partial pressure allows more accurate assessment of proportional response for assignment of pO2 "correction factors." Differences between instruments may also be investigated in closer detail.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Elser, J Sitler, C Garver. 1982. A flexible and versatile program for blood-gas quality control.. https://doi.org/10.1093/ajcp%2F78.4.471

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Laparoscopic surgery impairs tissue oxygen tension more than open surgery.

BACKGROUND: Wound infection remains a common and serious complication after colonic surgery. Although many colonic operations are performed laparoscopically, it remains unclear whether this has any impact on the incidence of wound infection. Subcutaneous tissue oxygenation is an excellent predictor of surgical wound infection. The impact of open and laparoscopic colonic surgery on tissue oxygenation was compared. METHODS: Fifty-two patients undergoing elective open and laparoscopic left-sided colonic resections were evaluated in a prospective observational study. Anaesthesia management was standardized and intraoperative arterial partial pressure of oxygen was kept at 150 mmHg in both groups. Oxygen tension was measured in the subcutaneous tissue of the right upper arm. RESULTS: At the start of surgery subcutaneous tissue oxygen tension (PsqO(2)) was similar in both groups (mean(s.d.) 65.8(17.2) and 63.7(23.6) mmHg for open and laparoscopic operations respectively; P = 0.714). Tissue oxygen remained stable in the open group, but dropped significantly in the laparoscopic group during the course of surgery (PsqO(2) after operation 53.4(12.9) and 45.5(11.6) mmHg, respectively; P = 0.012). CONCLUSION: Laparoscopic colonic surgery significantly decreases PsqO(2), an effect that occurs early in the course of surgery. As tissue oxygen tension is a predictor of wound infection, these results may explain why the risk of wound infection after laparoscopic surgery remains higher than expected.

Blood Gas Analysis↗

Open and closed endotracheal suction systems in mechanically ventilated intensive care patients: a meta-analysis.

BACKGROUND: Closed suction systems (CSS) are increasingly replacing open suction systems (OSS) to perform endotracheal toilet in mechanically ventilated intensive care unit patients. Yet effectiveness regarding patient safety and costs of these systems has not been carefully analyzed. OBJECTIVE: To review effectiveness of CSS and OSS, with respect to patient outcome, bacterial contamination, and costs in adult intensive care unit patients. DATA SOURCE: Search of MEDLINE, CINAHL, EMBASE, and Cochrane databases and a manual review of article bibliographies. STUDY SELECTION: Randomized controlled trials comparing CSS and OSS in adult intensive care unit patients were retrieved. DATA EXTRACTION/SYNTHESIS: Assessment of abstracts and study quality was performed by two reviewers. Data were combined in meta-analyses by random effect models. Fifteen trials were identified. No significant differences were found in incidences of ventilator-associated pneumonia (eight studies, 1,272 patients) and mortality (four studies, 1,062 patients). No conclusions could be drawn with respect to arterial oxygen saturation (five studies, 109 patients), arterial oxygen tension (two studies, 19 patients), and secretion removal (two studies, 37 patients). Compared with OSS, endotracheal suctioning with CSS significantly reduced changes in heart rate (four studies, 85 patients; weighted mean difference, -6.33; 95% confidence interval, -10.80 to -1.87) and changes in mean arterial pressure (three studies, 59 patients; standardized mean difference, -0.43; 95% confidence interval, -0.87 to 0.00) but increased colonization (two studies, 126 patients; relative risk, 1.51; 95% confidence interval, 1.12-2.04). CSS seems to be more expensive than OSS. CONCLUSIONS: Based on the results of this meta-analysis, there is no evidence to prefer CSS more than OSS.

Blood Gas Analysis↗