PubMed Health⌕ Search

PubMed · 6832506

Newborn hearing screening using the Linco-Bennett auditory response cradle: a pilot study.

Abstract

A modified mass newborn hearing screening program was piloted using a combination of a simplified high-risk register and a newly developed automated screening device, the Auditory Response Cradle. The program was designed to handle a total of 4000 babies per year. All children participating received both the high-risk register review and the automated screening test. The Auditory Response Cradle used a binaurally presented high-pass noise through a closed acoustic system at an intrameatally monitored level of 85 dB SPL (re 20 mu Pa) +/- 3 dB. Three independent motor and two respiratory response channels were monitored by the controlling microprocessor unit during a 5-sec prestimulus interval, and a 5-sec stimulus interval. Typical time for a complete test ranged from 5 to 10 min. The results of the present work indicate a false positive rate at or below 1.5%. The described program appears to be a cost-effective means of providing a mass neonatal hearing screening.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N T Shepard. Newborn hearing screening using the Linco-Bennett auditory response cradle: a pilot study.. https://doi.org/10.1097/00003446-198301000-00004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel homogenous time-resolved fluorometric RT-PCR assays for quantification of PSA and hK2 mRNAs in blood.

OBJECTIVES: The purpose of this study was to design, validate, and optimize internally standardized real-time quantitative RT-PCR assays and to identify and avoid problems with assay reliability and examine the impact of an exogenous internal standard. DESIGN AND METHODS: The model system consisted of internally standardized quantitative real-time RT-PCR assays specific for PSA and hK2 mRNA based on time-resolved fluorometric detection of lanthanide chelates. RESULTS: Reproducibility was best when large copy numbers (>5000 per milliliter blood) were analyzed. Addition of an exogenous target-mimicking internal standard had no significant effect on the reproducibility of the method, but increased the calculated copy numbers by an average of 2-fold. CONCLUSIONS: We developed an internally standardized, specific and reproducible real-time RT-PCR analysis method for PSA and hK2 mRNA in circulating cells in the bloodstream. Both PSA and hK2 assays are sufficiently sensitive to detect two LNCaP cells per milliliter whole blood.

False Positive Reactions↗