Fluorescence fluctuation immunoassay.

Abstract

The homogeneous fluorescent immunoassay described above allows one to measure the brightness of fluorescently tagged carrier particles that are suspended in a background of free, unbound fluorescent sources. We have demonstrated the feasibility of our technique using a gentamicin competitive assay as well as idealized model systems. We have seen that the fluctuation-correlation method is able to discriminate against free background sources because each fluorescing particle in solution contributes to the correlation peak [Eq. (4)] with a weighting equal to the square of its respective intensity. Hence, a few very bright sources contribute disproportionately to the "signal" relative to many weak ones. To take advantage of this property, one would therefore design an assay that uses relatively larger carrier particles, each of which is capable of binding on the order of 10(3) to 10(4) tagged antibodies or antigens. Unfortunately, the nonlinear dependence of the correlation peak on the brightness of the fluorescing species causes the technique to be perturbed by carrier particle aggregation; the apparent bound fluorescence intensity increases with the extent of aggregation. The latter may be an unavoidable consequence of performing assays using raw blood serum, for example. The ultimate usefulness of this method will depend on its sensitivity and speed when applied to "real" assays of clinical significance. These characteristics will be influenced by a number of technical details. Given our limited experience with the method thus far, it would appear that its principal drawback is its relatively slow speed. In order to decrease the time needed for a reliable measurement, one must average the random fluctuations in the fluorescent intensity to zero more quickly. In principle, this can be accomplished by decreasing the shot noise by collecting a larger fraction of the fluorescent light, and increasing the sampling rate. The method requires rather complicated instrumentation; it is by no means clear that this level of complexity is justified given the realistic level of sensitivity that will be obtained by this technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V B Elings, D F Nicoli, J Briggs. 1983. Fluorescence fluctuation immunoassay.. https://doi.org/10.1016/0076-6879(83)92039-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multianalyte immunoassay based on insulating-controllable PoPD film at arrayed electrodes integrated on a silicon chip.

A novel, simple and label-free multianalyte immunoassay system is presented here by integrating arrayed electrodes on a silicon chip via MEMS. The chip is consisted of six Au disk electrodes, an Au counter electrode and an Ag/AgCl reference electrode. Semi-insulating poly(o-phenylenediamine) (PoPD) was utilized to co-polymerize and immobilize antibodies at the arrayed Au electrodes, and wider linear detection range was obtained than those prepared with completely insulating PoPD. Electrochemical cyclic voltammogram (CV), AC impedance spectroscopy, AFM and fluorescence microscopy were employed to characterize the system. The arrayed electrodes offered exact control of deposition position via electrochemical operation, allowing selectively immobilization of different antibodies at desired positions on a single chip. Specific recognition of antibody (Ab) to corresponding antigen (An) was quantitatively monitored by cyclic voltammograms in the presence of electrochemical redox probe, ferrocene methanol. The proposed immunoassay chips showed sensitive response to three liver fibrosis markers, hyaluronic acid (HA), collagen type IV (IV-C) and lamin (LN) at ng/mL level simultaneously and specifically in a tiny amount of volume, usually 50 microL. The results obtained via chips were well consistent with those obtained by commercial radio immunoassays (RIA).

Antigens↗

The fibrinogen antigenic turbidimetric assay (FIATA): the X2x test--the corrected chi-square comparison against the control-mean.

Vancomycin precipitates fibrinogen. The turbidity induced by this vancomycin-fibrinogen interaction is used to establish a simple standardized antigenic assay for plasmatic fibrinogen, the FIATA. 1 mM vancomycin or 2 mM chloramine-T inactivates 50% of fibrinogen in human plasma. In contrast to chloramine-T, vancomycin does not react in NaJ-based photometric assay for chloramines,vancomycin does not inactivate the singlet oxygen-sensible antithrombin III, and the vancomycin action against fibrinogen is not changed in spite of the presence of the 1O2 quenchers methionine or ascorbic acid. The FIATA is performed as follows: to 25 microL plasma 50 microL PBS are added and the absorbance (A) at 405 nm is read. Then 50 microL FIATA-reagent, consisting of 4.4 mM vancomycin in PBS, are added. After 2 minutes (RT) DeltaA is determined and standardized against a plasma pool of 100% of norm (2.8 g/L) fibrinogen. The FIATA is nearly linear up to a fibrinogen concentration of about 150% of norm (4.2 g/L), resulting in a DeltaA of about 600 mA. The lower detection limit is 4% of norm (0.1 g/L). The intra-assay and interessay CV values are < 4%. The normal range of FIATA is 100% +/-20% (x- +/- 1 SD). In = 321 or 344 unselected patient plasmas the FIATA (x- = 130%; SD = 52% or 43%) correlated with the functional fibrinogen assays a) modified Clauss-Method (x- = 4.1 g/L; SD =1.7 g/L) with r = 0.755 and b) FIFTA (x- = 124%; SD = 40%) with r = 0.813. The vancomycin/fibrinogen interaction (binding of about 16 molecules of vancomycin/molecule of fibrinogen) can be used to purify fibrinogen out of plasma. Vancomycin also clouds dysfunctional fibrinogen (fibrinogen in presence of EDTA or chloramine-T)or soluble fibrin. Vancomycin-reacted fibrinogen stimulates tissue type plasminogen activator (t-PA) up to about 20-fold. The experimental data are analyzed by a new significance test: the two foldYates-corrected chi-square comparison against the mean value ofthe control-collective, called the Chi2x - Test. The P < .05 significance barrier calculated with the Chi2x - Test is equivalent to that calculated with the Fisher's Exact Test. The FIATA might be considered an interesting screening test for inactive fibrinogen forms or soluble fibrin, as eg in disseminated intravascular coagulation. Fibrinogen precipitation by vancomycin within the blood vessel might explain why vancomycin has to be infused slowly (< 10 mg/min) to prevent nephrotoxicity. The FIATA is of such a simplicity that the determination of fibrinogen antigen in plasma can be performed anywhere--even outside a hospital--within seconds. Thus, the presented FIATA might contribute to extra hospital testing of patients for assessing their risk for myocardial or cerebral ischemia/infarction.

Antigens↗